The Filtration, Oxidation and Pressure Drop Characteristics of a Catalyzed Particulate Filter during Active Regeneration – A 1D Modeling Study
Technical Paper
2009-01-1274
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Active regeneration of a catalyzed particulate filter (CPF) is affected by a number of parameters specifically particulate matter loading and inlet temperature. The MTU 1-D 2-Layer CPF model [1] was used to analyze these effects on the pressure drop, oxidation and filtration characteristics of a CPF during active regeneration. In addition, modeling results for post loading experiments were analyzed to understand the difference between loading a clean filter as compared to a partially regenerated filter.
Experimental data obtained with a production Cummins regenerative particulate filter for loading, active regenerations and post loading experiments were used to calibrate the MTU 1-D 2-Layer CPF model. The model predicted results are compared with the experimental data and were analyzed to understand the CPF characteristics during active regeneration at 1.1, 2.2 and 4.1 g/L particulate matter (PM) loading and CPF inlet temperatures of 525, 550 and 600°C. The activation energies for thermal oxidation reported in Chilumukuru et al. [2] were used and confirmed by these modeling results.
The model results showed that the pressure drop during active regeneration at 525, 550 and 600°C CPF inlet temperature is a function of PM loading. The pressure drop across the CPF has a higher rate of decay for higher temperatures. Analysis of model results showed that the peak pressure drop is a function of CPF inlet temperature at the same PM loading. The model results for all experiments targeted to up to 70% PM oxidation showed that the total filtration efficiency across the CPF during active regeneration is over 99%. Model results for post loading showed that the pressure drop across the CPF is lower compared to loading for the same amount of PM present in the CPF. The difference in pressure drop between loading and post loading was correlated to the wall pressure drop which is directly proportional to the mass of PM in the wall.
Recommended Content
Authors
- Rohith Arasappa - Michigan Technological University
- Kiran C. Premchand - Michigan Technological University
- Krishna P. Chilumukuru - Michigan Technological University
- John H. Johnson - Michigan Technological University
- Jeffrey Naber - Michigan Technological University
- Song-Lin Yang - Michigan Technological University
Citation
Arasappa, R., Premchand, K., Chilumukuru, K., Johnson, J. et al., "The Filtration, Oxidation and Pressure Drop Characteristics of a Catalyzed Particulate Filter during Active Regeneration – A 1D Modeling Study," SAE Technical Paper 2009-01-1274, 2009, https://doi.org/10.4271/2009-01-1274.Also In
References
- Premchand, K.C. Johnson, J. H. Yang. S.L. “Development of a 1-D CPF Model to Simulate Active Regeneration of a Diesel Particulate Filter.” SAE:2009-01-1283 2009
- Chilumukuru, K. P. Arasappa, R. Johnson, J. H. Naber. J. D. “An Experimental Study of PM Thermal Oxidation Rates for a Catalyzed Particulate Filter during Active Regeneration.” SAE:2009-01-1474 2009
- Suresh, A. Yezerets, A. Currier N. Clerc. J. “Diesel Particulate Filter System – Effect of Critical Variables on the Regeneration Strategy Development and Optimization.” SAE:2008-01-0329 2008
- Koltsakis, G. C. Haralampous, O. A. Dardiotis C. K. Samaras. Z. C. “Performance of Catalyzed Particulate Filters without Upstream Oxidation Catalyst.” SAE:2005-01-0952 2005
- Koltsakis, G. C. Dardiotis C. K. Samaras, Z. C. Frey, M. Wenninger G. Krutzsch, B. Haralampous. O. A. “Model-based Optimization of Catalyst Zoning in Diesel Particulate Filters.” SAE:2008-01-0445 2008
- Frey, M. Wenninger, G. Krutzsch, B. Koltsakis, G. C. Haralampous, O. A. Samaras. Z. C. “2D Simulation of the Regeneration Performance of a Catalysed DPF for Heavy-Duty Applications.” May. Topics in Catalysis 42 43 2007
- Ohyama, N. Nakanishi T. Daido. S. “New Concept Catalyzed DPF for Estimating Soot Loadings from Pressure Drop.” SAE:2008-01-0620 2008
- Singh, P. Thalagavara, A. M. Naber, J. D. Johnson J.H. Bagley. S. T. “An Experimental Study of Active Regeneration of an Advanced Catalyzed Particulate Filter by Diesel Fuel Injection Upstream of an Oxidation Catalyst.” SAE:2006-01-0879 2006
- Mohammed, H. Triana, A. P. Yang S.L. Johnson. J. H. “An Advanced 1D 2-Layer Catalyzed Diesel Particulate Filter Model to Simulate: Filtration by the Wall and Particulate Cake, Oxidation in the Wall and Particulate Cake by NO2 and O2, and Regeneration by Heat Addition.” SAE:2006-01-0467 2006
- Premchand, K. C. Johnson, J. H. Yang S.L. Triana A. P. Baumgard. K. J. “A Study of the Filtration and Oxidation Characteristics of a Diesel Oxidation Catalyst and a Catalyzed Particulate Filter.” SAE:2007-01-1123 2007
- Bisset, J. “Mathematical Model of the thermal Regeneration of a Wall-flow Monolith Diesel Particulate Filter.” Chem. Eng. Sci. 39 1983
- Konstandopoulos, A.G. Kostoglou, M. Skaperdas, E. Papaioannou, E. Zarvalis, D. Kladopoulou.,. E. “Fundamental Studies of Diesel Particulate Filters: Transient Loading, Regeneration and Aging.” SAE:2000-01-1016 2000
- Konstandopoulos. A.G. “Flow Resistance Descriptors for Diesel Particulate Filters: Definitions, Measurements and Testing.” SAE:2003-01-0846 2003
- Versaevel, P. Colas, H. Rigaudeau, R.N. Kolstakis, G.C. Stamatelos. A.M. “Some Empirical Observations on Diesel Particulate Filter Modeling and Comparison Between Simulations and Experiments.” SAE:2000-01-0477 2000
- Burtscher, H. “Physical characterization of particulate emissions from diesel engines: a review.” Aerosol Science 36 896 932 2005
- Konstandopoulos, A.G. Kostoglou, M. “Periodically Reversed Flow Regeneration of Diesel Particulate Traps.” SAE:1999-01-0469 1999