Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13
Technical Paper
2007-01-3214
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
The crews of Expeditions 12 and 13 aboard the International Space Station (ISS) continued to rely on potable water from two different sources, regenerated humidity condensate and Russian ground-supplied water. The Space Shuttle launched twice during the 12-months spanning both expeditions and docked with the ISS for delivery of hardware and supplies. However, no Shuttle potable water was transferred to the station during either of these missions.
The chemical quality of the ISS onboard potable water supplies was verified by performing ground analyses of archival water samples at the Johnson Space Center (JSC) Water and Food Analytical Laboratory (WAFAL). Since no Shuttle flights launched during Expedition 12 and there was restricted return volume on the Russian Soyuz vehicle, only one chemical archive potable water sample was collected with U.S. hardware and returned during Expedition 12. This sample was collected in March 2006 and returned on Soyuz 11. The number and sensitivity of the chemical analyses performed on this sample were limited due to low sample volume. Shuttle flights STS-121 (ULF1.1) and STS-115 (12A) docked with the ISS in July and September of 2006, respectively. These flights returned to Earth with eight chemical archive potable water samples that were collected with U.S. hardware during Expedition 13. The average collected volume increased for these samples, allowing full chemical characterization to be performed.
This paper presents a discussion of the results from chemical analyses performed on Expeditions 12 and 13 archive potable water samples. In addition to the results from the U.S. samples analyzed, results from pre-flight samples of Russian potable water delivered to the ISS on Progress vehicles and in-flight samples collected with Russian hardware during Expeditions 12 and 13 and analyzed at JSC are also discussed.
Authors
Citation
Straub, J., Plumlee, D., and Schultz, J., "Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13," SAE Technical Paper 2007-01-3214, 2007, https://doi.org/10.4271/2007-01-3214.Also In
References
- Mudgett P.D. et al. Quality of Water Supplied by Shuttle to ISS SAE Paper 2002-01-2532 . 32 nd International Conference on Environmental Systems San Antonio, TX July 2002
- ISS Medical Operations Requirements Document SSP 50260, Revision C NASA Johnson Space Center, Section 7.2.2. February 2006
- Straub J.E et al. ISS Expeditions 10 & 11 Potable Water Sampling and Chemical Analysis Results SAE Paper 2006-01-2015 . 36 th International Conference on Environmental Systems Norfolk, Virginia July 2006
- Straub J.E. et al. Chemical Analysis of ISS Potable Water from Expeditions 8 and 9 SAE Paper 2005-01-2885 . 35 th International Conference on Environmental Systems Rome, Italy July 2005
- Straub J.E. et al. ISS Potable Water Sampling and Chemical Analysis: Expeditions 6 & 7 SAE Paper 2004-01-2537 . 34th International Conference on Environmental Systems Colorado Springs Colorado July 2004
- Plumlee D.K. et al. ISS Potable Water Sampling and Chemical Analysis: Expeditions 4 & 5 SAE No. 2003-01-2401 . 33rd International Conference on Environmental Systems Vancouver, BC July 2003
- Plumlee D.K. et al. Chemical Sampling and Analysis of ISS Potable Water: Expeditions 1-3 SAE Paper 2002-01-2357 . 32nd International Conference on Environmental Systems San Antonio, TX July 2002
- United States Environmental Protection Agency, Office of Water Drinking Water Standards and Health Advisories, EPA 822-B-00-001 2000
- James J.T. Di (2-ethyhexyl) Phthalate , Chapter 4, Table 4-10 Spacecraft Water Exposure Guidelines for Selected Contaminants 1 The National Academies Press 2004