Detection of Deteriorated Catalyst on Vehicle under Actual Operation Conditions: Application of FFT Analysis to Signal Wave by the Dual Oxygen Sensors Method

2007-01-1927

07/23/2007

Event
JSAE/SAE International Fuels & Lubricants Meeting
Authors Abstract
Content
The object of this study is to investigate an on-board diagnostic method to detect the deterioration of a three-way catalyst (TWC) under actual vehicle operating conditions, including the acceleration state. The signal data of two oxygen sensors were processed by the fast Fourier transformation (FFT) method. As a result, we found that the power spectrum of the signal waves can be the index of catalyst deterioration degree. Furthermore, it was confirmed that the difference between the power spectrum of the upstream oxygen sensor signal and one of the downstream oxygen sensor signal named ΔPower is effective index for detection of deteriorated catalyst under acceleration conditions.