This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Using a Sweating Manikin, Controlled by a Human Physiological Model, to Evaluate Liquid Cooling Garments
Technical Paper
2005-01-2971
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
An Advanced Automotive Manikin (ADAM), is used to evaluate liquid cooling garments (LCG) for advanced space suits for extravehicular applications and launch and entry suits. The manikin is controlled by a finite-element physiological model of the human thermoregulatory system.
ADAM's thermal response to a baseline LCG was measured.The local effectiveness of the LCG was determined. These new thermal comfort tools permit detailed, repeatable measurements and evaluation of LCGs. Results can extend to other personal protective clothing including HAZMAT suits, nuclear/biological/ chemical protective suits, fire protection suits, etc.
Authors
Citation
Farrington, R., Rugh, J., Bharathan, D., Paul, H. et al., "Using a Sweating Manikin, Controlled by a Human Physiological Model, to Evaluate Liquid Cooling Garments," SAE Technical Paper 2005-01-2971, 2005, https://doi.org/10.4271/2005-01-2971.Also In
References
- CSM/LM Spacecraft Operational Data Book IV EMU Data Book 1971 1 3
- NASA Extravehicular Mobility Unit (EMU) LSS/SSA Data Book 2004 Hamilton Sunstrand
- Kuznetz, L. H. 1977 Shuttle/Apollo Liquid Cooling Garment Cooling Efficiency Comparison Quick Look Test Report
- Kuznetz, L. H. 1977 Automatic Control of Human Thermal Comfort with a Liquid-Cooled Garment NASA TM-58205
- Kuznetz, L. H. 1976 Control of Thermal Balance by a Liquid Circulating Garment Based on a Mathematical Representation of the Human Thermoregulatory System
- Graves, G. 1978 Relationship of UA to LCVG coolant flow rate and inlet temperature
- Smith, E. 1978 Establishing a Minimum UA for the LCG
- Iovine, J. V. 1987 Liquid Cooling Garment Automatic Thermal Control Test Summary
- Bue, G. C. 1989 “Computer Program Documentation 41-Node Transient Metabolic Man Program,”
- Dunaway, B. 1988 Automatic Liquid and Ventilation Cooling Garment Control Algorithm Final Test Report
- Smith, G. Pantermuehl, J. 1992 Segmented Liquid Cooled Garment Final Test Report
- Smith, G. Schneider, S. Keilich, M. Conger, B. 1992 Crew Member/Extravehicular Mobility Unit Thermal Interactions Affecting Cooling Preferences and Metabolic Water Removal 25th International Conference on Environmental Systems SAE 951637
- Koscheyev, V. Leon, G. Trevino, R. 2002 An Advanced Physiological Based Shortened Liquid Cooling/Warming Garment for Comfort Management in Routine and Emergency EVA 32nd International Conference on Environmental Systems SAE 2002-01-2413
- Koscheyev, V. Leon, G. Coca A. Ferl, J. Graziosi, D. 2004 Comparison of Shortened and Standard Liquid Cooling Garments to Provide Physiological and Subjective Comfort 34nd International Conference on Environmental Systems SAE 2004-01-2347
- Farrington, R. Rugh, J. Bharathan, D. Burke, R. 2004 Use of a Thermal Manikin to Evaluate Human Thermoregulatory Responses in Transient, Non-Uniform, Thermal Environments 4th International Conference on Environmental Systems SAE 2004-01-2345 Colorado Springs, CO.
- Burke, R. Rugh, J. Farrington R. 2003 ADAM - the Advanced Automotive Manikin 5th International Meeting on Thermal Manikins and Modeling Strasbourg, France
- Gordon, R. G. Roemer, R. B. Horvath, S. M. 1976 A Mathematical Model of the Human Temperature Regulatory System - Transient Cold Exposure Response IEEE Transactions on Biomedical Engineering 23 6 434 444
- Smith, C. E. 1991 A Transient, Three-Dimensional Model of the Human Thermal System Kansas State University
- Zhang, H. Huizenga, C. Arens E. 2003 Thermal Sensation and Comfort in a Transient Non-Uniform Thermal Environment 5th International Meeting on Thermal Manikins and Modeling
- Zhang, H. 2004 Human Thermal Sensation and Comfort in Transient and Non-Uniform Thermal Environments U.C. Berkeley