Columbus Active Thermal Control Equipment Development
Technical Paper
2005-01-2769
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
The Columbus laboratory module for the International Space Station (ISS) uses active thermal control for cooling of avionics and payload in the pressurized compartment. The Active Thermal Control Subsystem (ATCS) is based on a water loop rejecting waste heat to the Medium Temperature Heat Exchanger and Low Temperature Heat Exchanger on Node 2, part of the US Segment of the ISS. Flow and temperature control in the ATCS is achieved by means of the Water Pump Assembly (WPA) and the 3-Way Modulating Valve (WTMO) units. For the flow control the WPA speed is commanded so that a fixed pressure drop is maintained over the plenum with the avionics and payload branches. Adjusting the WTMO internal flow split permit the two active units to perform the CHX and plenum inlet temperature control.
The WPA includes a filter and an accumulator to control the pressure in the ATCS and to compensate for leakage and temperature-dependent volume variations. A gas trap will be inserted into the loop at the WPA interface for the event that bubbles have to be vented from the ATCS water. The ATCS loop redundancy is implemented by the use of two sets each consisting of one WPA unit and two WTMO units. For maintenance or in the event of failure it is possible to re-configure to the redundant units without the need to interrupt Columbus operations.
The purpose is to present the design and the analytical and test activities which have culminated in qualification and acceptance of the equipment. An example of the challenges, which had to be faced in the course of the development and verification, is the gas trap. Surfacing difficulties with the automatically operated membrane type unit have forced a re-orientation towards a manually operated hydrocyclone-based design.
Recommended Content
Authors
Citation
Mascellani, E., Pavarani, A., Vaccaneo, P., Szigetvari, Z. et al., "Columbus Active Thermal Control Equipment Development," SAE Technical Paper 2005-01-2769, 2005, https://doi.org/10.4271/2005-01-2769.Also In
References
- WPA Hydrocyclone OSE PFM Test Plan 1 23 December 2003
- WPA Operations Manual 2 13 September 2004
- Columbus Design Definition Report 6 27 August 2004
- WPA Design Definition Report 5 9 May 2003
- WTMO Design Definition Report 4 10 April 2002
- WPA Qualification Test Campaign Overview 2 20 June 2003
- WTMO Qualification Test Campaign Overview 3 9 May 2002