Jet Fuel Vapor Ignition within a Duct Thermal Insulation

2004-01-2574

07/19/2004

Event
International Conference On Environmental Systems
Authors Abstract
Content
A test setup was built to identify the ignition of jet fuel vapor-air mixtures within an insulation media and induced by a hot duct surface. The external diameter of the duct was 76.2 mm (3 inches) and covered with a 12.7 mm (0.5 inch) layer of ceramic fiber insulation, which had its pores completely filled with fuel vapor and air mixtures. The ignition was detected by thermocouples installed in insulation media and confirmed by chromatography and mass spectrometry. In order to design the experimental apparatus and allow behavior investigation in other operational conditions, a mathematical model was developed.
Meta TagsDetails
DOI
https://doi.org/10.4271/2004-01-2574
Pages
11
Citation
da Silva, G., Barbosa, R., and de Jesus Zerbini, E., "Jet Fuel Vapor Ignition within a Duct Thermal Insulation," SAE Technical Paper 2004-01-2574, 2004, https://doi.org/10.4271/2004-01-2574.
Additional Details
Publisher
Published
Jul 19, 2004
Product Code
2004-01-2574
Content Type
Technical Paper
Language
English