Development of an FE Flexible Pedestrian Leg-form Impactor (Flex-PLI 2003R) Model and Evaluation of its Biofidelity

2004-01-1609

03/08/2004

Event
SAE 2004 World Congress & Exhibition
Authors Abstract
Content
A biofidelic flexible pedestrian leg-form impactor, called Flex-PLI, was developed by the Japan Automobile Manufactures Association, Inc. (JAMA) and the Japan Automobile Research Institute (JARI). Its latest version is called Flex-PLI 2003. The Flex-PLI 2003 responses have been validated at the component level (thigh, leg, and knee independently) but not at the assembly level (thigh-knee-leg complex). Furthermore, there was no FE Flex-PLI model.
This research developed a FE Flex-PLI 2003R model (Flex-PLI 2003R means that the thigh and leg mass of Flex-PLI 2003 is adjusted to AM 50). The FE Flex-PLI 2003R model biofidelity has been evaluated at both the component level and the assembly level, where it demonstrated high biofidelity.
Meta TagsDetails
DOI
https://doi.org/10.4271/2004-01-1609
Pages
11
Citation
Konosu, A., and Tanahashi, M., "Development of an FE Flexible Pedestrian Leg-form Impactor (Flex-PLI 2003R) Model and Evaluation of its Biofidelity," SAE Technical Paper 2004-01-1609, 2004, https://doi.org/10.4271/2004-01-1609.
Additional Details
Publisher
Published
Mar 8, 2004
Product Code
2004-01-1609
Content Type
Technical Paper
Language
English