Time-Resolved Measurements of Exhaust PM for FTP-75:Comparison of LII, ELPI, and TEOM Techniques

2004-01-0964

03/08/2004

Event
SAE 2004 World Congress & Exhibition
Authors Abstract
Content
A direct comparison is made of time-resolved measurements of diesel PM emissions obtained using laser-induced incandescence (LII), an electrical low pressure impactor (ELPI), and a tapered element oscillating microbalance (TEOM). The measurements were made on two diesel passenger vehicles, one of which was equipped with a diesel particulate filter. Both LII and the ELPI performed well for both vehicles, whereas the TEOM lacked the sensitivity required for the filtered vehicle. We estimate that the LII system used has a limit of detection better than 0.2 mg/mi.
Meta TagsDetails
DOI
https://doi.org/10.4271/2004-01-0964
Pages
13
Citation
Witze, P., Chase, R., Maricq, M., Podsiadlik, D. et al., "Time-Resolved Measurements of Exhaust PM for FTP-75:Comparison of LII, ELPI, and TEOM Techniques," SAE Technical Paper 2004-01-0964, 2004, https://doi.org/10.4271/2004-01-0964.
Additional Details
Publisher
Published
Mar 8, 2004
Product Code
2004-01-0964
Content Type
Technical Paper
Language
English