This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
High Frequency Low Amplitude Temperature Oscillations in Loop Heat Pipe Operation
Technical Paper
2003-01-2387
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
The operating temperature of a loop heat pipe (LHP) with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator power, condenser sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will also change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. This paper presents a study on the oscillation of the loop operating temperature with amplitudes on the order of 1 Kelvin and periods on the order seconds to minutes. The source of the high frequency temperature oscillation is the fast movement of the vapor front in the condenser section, which usually occurs when the vapor front is near the condenser inlet or the condenser outlet. At these locations, the vapor front is unable to find a stable position for the given operating condition, and will move back and forth. The oscillation of the vapor front causes an oscillation of the liquid flow in the condenser and liquid line, leading to an oscillation of the CC and loop temperatures. Factors that affect the vapor front movement include evaporator power, condenser sink temperature, body forces and whether or not the CC temperature is actively controlled. As long as there are no large thermal masses attached to the evaporator, the loop can self adjust rather quickly and the vapor front will move rapidly around the condenser inlet or outlet, leading to high frequency temperature oscillations. The amplitude of temperature oscillation is usually the largest in the liquid line, up to 20 Kelvin in many cases, but diminishes to less than 1 Kelvin in the CC. Furthermore, the high frequency temperature oscillation can occur at any CC temperature with the "right" combinations of the evaporator power and condenser sink temperature.
Recommended Content
Authors
Topic
Citation
Ku, J., "High Frequency Low Amplitude Temperature Oscillations in Loop Heat Pipe Operation," SAE Technical Paper 2003-01-2387, 2003, https://doi.org/10.4271/2003-01-2387.Also In
References
- Orlov, A. Gocharov, K. Kotlyarov, E. Tyklina, T. The Heat Pipe Experimental Onboard the Granat Spacecraft 6th European Symposium on Space Environmental Control Systems Noordwijk, Netherlands 1997
- Ottenstein, L. Ku, J. Feenan, D. Thermal Vacuum Testing of a Novel Loop Heat Pipe Design for the Swift BAT Instrument Space Technology and Applications International Forum - 2003 Albuquerque, New Mexico February 2-6 2003
- Grob, E. System Accommodation of Propylene Loop Heat Pipes for The Geoscience Laser Altimeter System (Glas)Instrument SAE Paper No. 2001-01-2263 2001
- Maidanik, Y. Fershtater, Y. Theoretical Basis and Classification of Loop Heat Pipes and Capillary Pumped Loops 10th International Heat Pipe Conference Stuttgart, Germany 1997
- Ku, J. Operating Characteristics of Loop Heat Pipes SAE Paper No. 1999-01-2007
- Goncharov, K. A., et al. Investigation of Temperature Fluctuations in Loop Heat Pipes SAE Paper No. 941577 1994
- Ku, J. Hoang, T. An Experimental Study of Pressure Oscillation and Hydrodynamic Stability in a Capillary Pumped Loop Proceedings of 31st National Heat Transfer Conference, ASME HTD 307 25 32 1995
- Hoang, T. Ku, J. Theory of Hydrodynamic Stability for Capillary Pumped Loops Proceedings of 31st National Heat Transfer Conference, ASME HTD 307 33 40 1995
- Debles, S. Ochterbeck, J. Effects of Condenser Two-Phase Flow Characteristics on a Capillary Pumped Loop ICES Paper No. 2000-01-2321 2000
- Ku, J., Ottenstein, L., Kobel, M. Rogers, P. Kaya, T. Temperature Oscillations in Loop Heat Pipe Operation STAIF 2001, American Institute of Physics Albuquerque, New Mexico February 11-14 2001
- Rodriguez, J. I. Na-Nakornpanom, A. Investigation of Transient Temperature Oscillations of a Propylene Loop Heat Pipe SAE Paper No. 2001-01-2235
- Muto, M. Nagai, H. Marakami, M. Ueno, S. Matsuoka, M. Thermal Behavior of a Double-Condenser Design LHP for Monitor of All-Sky X-Ray Image SAE Paper No. 2002-01-2505 2002
- Sasin, V.Y. Zelenov, I.A. Zuev, V.G. Kotlyarov, E.Y. Mathematical Model of a Capillary Loop Heat Pipe with a Condenser-Radiator SE Paper No. 901276 1990
- Ku, J. Rodriquez, J. Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation SAE Paper No. 2003-01-2386 2003
- Ku, J. Ottenstein, L. Rogers, P. Cheung, K. Effect of Pressure Drop on Loop Heat Pipe Operating Temperature 12th International Heat Pipe Conference May 19-24 Moscow, Russia