Oil Circulation Ratio in CO2 Climate Control Systems
Technical Paper
2003-01-0730
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
This paper presents the effect of the oil circulation ratio on the system performance of a CO2 climate control system and the effect of an oil separator on the oil circulation behavior using a new oil circulation ratio measurement method. In this study, the oil circulation ratio of a CO2/PAG mixture at various system conditions was measured. When the oil circulation ratio increases from 0.5 wt.% to 7 wt.%, the coefficient of performance decreases by 8% and 11% for idling and driving conditions, respectively. Without the oil separator, the oil circulation ratio increases more than 10 wt.%; with the oil separator, it was maintained at below detection level and 1.1 wt.% for idling and driving conditions, respectively.
Recommended Content
Authors
- Yunho Hwang - Center for Environmental Energy Engineering, University of Maryland
- Lorenzo Cremaschi - Center for Environmental Energy Engineering, University of Maryland
- Reinhard Radermacher - Center for Environmental Energy Engineering, University of Maryland
- Toshio Hirata - Denso Corp.
- Yukikatsu Ozaki - Nippon Soken Inc.
- Tadashi Hotta - Nippon Soken Inc.
Citation
Hwang, Y., Cremaschi, L., Radermacher, R., Hirata, T. et al., "Oil Circulation Ratio in CO2 Climate Control Systems," SAE Technical Paper 2003-01-0730, 2003, https://doi.org/10.4271/2003-01-0730.Also In
References
- ASHRAE 1996 ANSI/ASHRAE Standard 41.4: Standard Method for Measurement of Proportion of Lubricant in Liquid Refrigerant Atlanta GA
- Baustian, J.J. Pate M.B. Bergles A.E. 1988 Measuring the Concentration of a Flowing Oil-Refrigerant Mixture with a Bypass Viscometer ASHRAE Transactions 94 588 601
- Baustian, J.J. Pate M.B. Bergles A.E. 1988 Measuring the Concentration of a Flowing Oil-Refrigerant Mixture with an Acoustic Velocity Sensor ASHRAE Transactions 94 602 615
- Fukuta, M. Yanagisawa T. Kinoshita E. Syogi Y. 1999 Measurements of Refrigerant Solubility in the Refrigeration Oil Transactions of JSRAE 16 3 239 242
- Hwang, Y. Cremaschi L. Radermacher R. Hirata T. Ozaki Y. Hotta T. 2002 Oil Circulation Ratio Measurement in CO 2 Cycle Proceedings of the 2002 International Conference-New Technologies in Commercial Refrigeration 22 28
- Meyer, J.J. Jabardo J.M.S. 1992 An Ultrasonic Device for Measuring the Oil Concentration in Flowing Liquid Refrigerant Univ. of Illinois at Urbana-Champaign
- Suzuki, S. Fujisawa Y. Nakazawa S. Matsuoka M. 1993 Measuring Method of Oil Circulation Ratio Using Light Absorption ASHRAE Transactions 99 413 421
- Zhao, Y. Molki M. Ohadi M. Franca F. Radermacher R. 2002 Flow Boiling of CO2 with Miscible Oil in Microchannels ASHRAE Transactions 108 4505