Abstract
The objective of this paper is to describe a turbochargers test bench capable of elaborating turbochargers maps, under pulsating or continuous flow conditions. With this experimental tool it is possible to obtain information about turbocharger performance at realistic engine operative points. Consequently, the experimental tool is able to complete and validate manufacturers turbochargers maps.
In order to deeply achieve these objectives, the turbocharger test bench is used in combination with a gas-dynamic code, which provides an accuracy simulation of the experimental installation. In addition, the obtained information will increase the power of modelling codes used for turbocharged engines design.
Recommended Content
Authors
Citation
Luján, J., Bermúdez, V., Serrano, J., and Cervelló, C., "Test Bench for Turbocharger Groups Characterization," SAE Technical Paper 2002-01-0163, 2002, https://doi.org/10.4271/2002-01-0163.Also In
References
- Dale, A. Watson, N. “Vaneless diffuser turbocharger turbine performance” Proc. Instn. Mech. Engrs. 65 76 1986
- Chen, H. Hakeem, I. Martínez-Botas, R.F. “Modelling of a turbocharger turbine under pulsating inlet conditions” Proc. Instn. Mech. Engrs. 210 397 408 1996
- Spence, S.W.T. Artt, D.W. “Experimental performance evaluation of a 99.0 mm radial inflow nozzled turbine with different stator throat areas” Proc. Instn. Mech. Engrs. 211 477 488 1997
- Naundorf, D. Bolz, H. Mandel, M. “Design and Implementation of a Hew Generation of Turbo Charger Test Benches Using Hot Gas Technology” SAE Paper 2001-01-0279 2001
- Stemler, E. Lawless, P. “The design and operation of a turbocharger test facility designed for transient simulation” SAE paper 970344 1997
- Luján, JM. Galindo, J. Serrano, JR. “Efficiency characterization of centripetal turbines under pulsating flow conditions” SAE Paper 2001-01-0272 2001