This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Studies on Enhanced CVS Technology to Achieve SULEV Certification
Technical Paper
2002-01-0048
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
For the measurement of exhaust emissions, Constant Volume Sampling (CVS) technology is recommended by legislation and has proven its practical capability in the past. However, the introduction of new low emission standards has raised questions regarding the accuracy and variability of the CVS system when measuring very low emission levels.
This paper will show that CVS has the potential to achieve sufficient precision for certification of SULEV concepts. Thus, there is no need for the introduction of new test methods involving high cost.
An analysis of the CVS basic equations indicates the importance of the Dilution Factor (DF) for calculating true mass emissions. A test series will demonstrate that, by adjusting the dilution and using state of the art analyzers, the consistency of exhaust results is comparable with those of LEV concepts, measured with conventional CVS systems and former standard analyzers.
Blank tests and vehicle emission tests demonstrate that emissions at SULEV level can be measured with high accuracy.
Finally, this paper discusses the influence of individual components of the CVS system on exhaust results. It suggests an enhanced CVS system that detects SULEV limits with high precision.
Recommended Content
Technical Paper | Further Investigation of Losses in NOx Recovery with a CVS |
Technical Paper | Japan Clean Air Program (JCAP)-Program Objectives and Design |
Technical Paper | Inspection and Maintenance of Cars In Use |
Authors
Topic
Citation
Behrendt, H., Mörsch, O., Seiferth, C., Seifert, G. et al., "Studies on Enhanced CVS Technology to Achieve SULEV Certification," SAE Technical Paper 2002-01-0048, 2002, https://doi.org/10.4271/2002-01-0048.Also In
References
- Mondt, J. Robert Cleaner cars: the history and technology of emission control since the 1960 Warrendale; PA 15096-001 USA 0-7680-0222-2
- AIGER Bag Mini Diluter Technical Exchange Meeting August 22-24 2000 Detroit
- Silvis W. M. Harvey R. N.I Dageforde A. F. A CFV Type Mini-dilution Sampling System for Vehicle Exhaust Emissions Measurement SAE 1999-01-0151
- Guenther K. Henney T. Silvis W.M. Nakatani S. Wu Dien-Yeh Improved Bag Mini-diluter Sampling System for Ultra-low Level Vehicle Exhaust Emissions SAE 2000-01-0792
- Gifhorn A. Tieber H. Wiebrecht J. W. Ballik R. Basic Investigations into the use of the CVS System for Ultra- low-emission Vehicles with Gasoline Engines MTZ 61 2000 2 106 MTZ Worldwide 61 2000 2 17
- 40 CFR 86.082-2 Definitions
- 40 CFR 86.109-94 Exhaust gas sampling system Otto-cycle vehicles not requiring particulate emission measurement
- 70/220/EEC 1999 102 EC
- Automobile Type Approval Handbook For Japanese Certification December 31 1993 Japan Automobile Standards Internationalization Center 5 Technical Standard for 10-Mode and 11-Mode Exhaust Emission Measurement for Gasoline-Fueled Motor Vehicles
- 40 CFR 86.144-90 Calculations
- Sherman M. T. Chase R. E. Lennon K. M. Error Analysis of Various Sampling Systems SAE 2001-01-0209
- Sun E.I. McMahon W. N. Evaluation of Fluorocarbon Polymer Bag Material for Near Zero Exhaust Emission Measurement SAE 2001-01-3535
- Sawano Yoda Uchida A Study of Low- Emission Measurement Techniques JSAE 9631010 1996
- HORIBA Europe procedure Sulzbach, Germany
- Correcting Negative Calculated Emission Levels to Zero United States Environmental Protection Agency February 8 2001
- Heckelmann J. Analyse und Verification verfahrenstechnischer Apparate zur Bereitstellung von stabiler und getrockneter Verdünnungsluft bei der CVS Abgasmessung Diplom Thesis Fachhochschule Heilbronn Institut für Verfahrenstechnik 2001