Measurement of Flame Front Structure and Its Thickness by Planar and Local Chemiluminescence of OH*, CH* and C2*
2001-01-0920
03/05/2001
- Event
- Content
- We have measured the local flame front structure and its thickness using high speed three CCD camera and Developed Cassegrain optics, which could measure local OH*, CH* and C2* radicals at a point. The time-series OH*, CH* and C2* planar images are compared to those measured by local radical. The results show that the CH* and C2* signals can be a nice marker of flame front structure and its thickness, while OH* has some uncertainty.
- Pages
- 10
- Citation
- Ikeda, Y., Nishihara, H., and Nakajima, T., "Measurement of Flame Front Structure and Its Thickness by Planar and Local Chemiluminescence of OH*, CH* and C2*," SAE Technical Paper 2001-01-0920, 2001, https://doi.org/10.4271/2001-01-0920.