Abstract
This paper describes the design and qualification of this SCIAMACHY Radiant Cooler and focuses on the methods and results of the thermal balance and thermal verification test of the Radiator Reflector Unit flight model, performed late summer 1998.
A new type of temperature control has been used that proved to increase speed, simplicity and accuracy of the test itself as well as the evaluation afterwards.
The RRU TB/TV test was successful in gathering all significant thermal parameters.
After refurbishment of the cooler door and a requalification test of its transient performance all cooler parameters are acceptable and its thermal performance is within specification.
Authors
Citation
Lemmen, M., Boslooper, E., and Coesel, R., "Thermal Qualification of the Sciamachy Passive Cryogenic Cooler," SAE Technical Paper 1999-01-2084, 1999, https://doi.org/10.4271/1999-01-2084.Also In
References
- Coesel, Rinus Cruijssen, Henk Wigbers, Ino The development of the Sciamachy Radiant Cooler 6th European Symposium on Space Environmental Control Systems 1 169 173 Noordwijk, The Netherlands 20-22 May 1997
- Lemmen, M.H.J. Coesel, M.J.N. Thermal balance test results of Sciamachy Thermal Bus Unit 6th European Symposium on Space Environmental Control Systems 1 233 237 Noordwijk, The Netherlands 20-22 May 1997