Evaluation of 5th Percentile Female Hybrid III Thoracic Biofidelity during Out-of-Position Tests with a Driver Air Bag

980636

02/23/1998

Event
International Congress & Exposition
Authors Abstract
Content
This paper evaluates the biofidelity of the Hybrid III 5th percentile female dummy relative to seven small female cadavers tested as out-of-position drivers in static air bag deployment tests. In the out-of-position tests, the chest was positioned against the air bag module in an effort to recreate a worst-case loading environment for the thorax. Two pre-depowered production air bags and a prototype dual-stage air bag were evaluated. Thoracic accelerometers and chestbands were used to compare chest compression, velocity, acceleration, and Viscous Criteria. A statistical comparison of dummy and cadaver results indicate acceptable biofidelity of the Hybrid III dummy with significant differences observed only in the Viscous Criteria.