Fitting and Coolant Line Insulation Design for International Space Station
Annotation ability available
Sector:
Language:
English
Abstract
International Space Station (ISS) will provide Low Temperature (LT), and Moderate Temperature (MT) Internal Thermal Control System (ITCS) coolant to payloads and other users. LT ITCS delivers 38° to 42° F coolant MT ITCS delivers 62° to 65° F coolant.
By using LT ITCS cabin air, dew point is controlled by the Thermal and Humidity Control (THC) subsystem to be 49° to 55° F when manned. Since the dew point temperature is above the LT ITCS nominal temperature, any components that have this coolant in them can be expected to condense moisture on their surfaces. The components that are affected are many. This paper, however, is concerned only with the lines and Quick Disconnects (QDs) that are a part of the total ITCS system.
Authors
Citation
Pengelly, S. and Burt, W., "Fitting and Coolant Line Insulation Design for International Space Station," SAE Technical Paper 961354, 1996, https://doi.org/10.4271/961354.Also In
References
- “Updated Lab Module Parametric Insulation Thicknesses,” Solomon, M.E. April 3 1993
- “Insulation Thicknesses for Additional Lab-A Module Equipment,” Solomon, M.E. August 9 1993
- “Lab TCS/THC Insulation Thermal Analysis,” Burt, W. A. October 12 1994
- “Lab Condensation Thermal Analysis Report,” Burt, W. A. September 26 1994
- “Maximum Expected Dew Points For the U.S. Lab Module,” Von Jouanne, R.G. November 10 1994
- “Internal Thermal Control Insulation Installation,” Pengelly, S.L. April 20 1995
- 1989 Fundamentals Handbook, American Society of Heating and Air Conditioning Engineering Book 20.16