A Micromachined Field Asymmetric-Ion Mobility Spectrometer for Detecting Volatile Organic Chemicals in Ambient Air
Technical Paper
2000-01-2436
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Drift tubes barely the size of a quarter coin have been created and shown to provide analytical performance for detecting volatile organic compounds (VOCs) in air with sensitivity and selectivity comparable to larger analyzers in ion mobility spectrometry (IMS). These new micro-scale drift tubes have been operated under high field radio frequency (RF) regimes so that ion shutters and aperture grids could be removed from the drift tube. This advance also allowed the prototype units to be made with a planar design using manufacturing methods suitable for mass production and low cost. Ion characterization and separation with an RF-IMS drift tube are based upon differential mobilities, of gas phase ions, between high field and low field limits. Analytical measurement performance for a VOCs in air are shown and discussed.
Authors
Citation
Eiceman, G., Nazarov, E., and Miller, R., "A Micromachined Field Asymmetric-Ion Mobility Spectrometer for Detecting Volatile Organic Chemicals in Ambient Air," SAE Technical Paper 2000-01-2436, 2000, https://doi.org/10.4271/2000-01-2436.Also In
References
- Eiceman G.A. Karpas Z. Ion Mobility Spectrometry CRC Press Boca Raton, FL 1994
- Reese E.S. Taraszewski S.J. Limero T.F. James J.T. “Near-real-time Analysis of Toxicologically Important Compounds Using the Volatile Organic Analyzer for the International Space Station” 8 th International Conference on Ion Mobility Spectrometry Buxton, UK August 8-12 1999
- Bradshaw R. “Engineering Approaches and Compromises in the Design of Small IMS Spectrometers,” 3 rd International Workshop on Ion Mobility Spectrometry Galveston, TX Oct. 16-19 1994 Harden C.S. “Relative Performance Characteristics of Handheld Ion Mobility Spectrometers-The Chemical Agent Monitor and a New Miniaturized Instrument” 5 th International Workshop on Ion Mobility Spectrometry Cambridge, UK August 1995
- Xu J. Whitten W. B. Ramsey J. M. “ Miniature Ion Mobility Spectrometry” 8 th International Workshop on Ion Mobility Spectrometry, Buxton UK Aug. 8-12 1999
- Baumbach J.I. Berger D. Leonhardt J.W. Klockow D. “Ion Mobility Sensor in Environmental Analytical Chemistry-Concept and First Result” Intl. J. Environ. Analy. Chem. 52 189 1993
- Miller, R.A. Eiceman, G.A. Nazarov E.G. “A Micromachined High-Field Asymmetric WaveformIon Mobility Spectrometer (FA-IMS)” Sensor and Actuators B. Chemical 2000
- Buryakov A. Krylov E. V. Makas' A. L. Nazarov E. G. Pervukhin V. V. Rasulev U. Kh. Sov. Tech. Phys. Lett 17 6 June 1991
- Buryakov I.A. Krylov E.V. Nazarov E.G. Rasulev U. Kh. Int. J. Mass Spectrometry and Ion Processes 128 143 148 1993
- Carnahan B. Day S. Kouznetsov V. Tarassov A. “Development and Applications of a Transverse Field Compensation Ion Mobility Spectrometer” 5 th International Workshop on Ion Mobility Spectrometry Cambridge, UK August 6-9 1995
- Carnahan B. Day S. Kouznetsov V. Matyjaszczyk M. Tarassov A. “Field Ion Spectrometry - A New Analytical Technology For Trace Gas Analysis”, Proceedings of the 1996 International Conference on Advances in Instrumentation and Control, ISA ’96
- Purves R.W. Guevremont R. Day S. Pipich C.W. Matyjaszczyk M.S. Review of Scientific Instruments 69 4094 4105 1998
- Guevremont R. Purves R.W. Review of Scientific Instruments 70 1370 1999
- Revercomb H.E. Mason E.A. Anal. Chem. 47 7 970 983 1975