ARP785B Procedure for the Determination of Particulate Contamination in Hydraulic Fluids by the Control Filter Gravimetric Procedure

Revised

12/03/2020

Features
Issuing Committee
Scope
Content
This ARP describes a gravimetric method for the determination of particulate contaminant in hydraulic fluids by the control filter technique.
NOTE: With this method, detectable contamination levels down to 0.2 mg (7.0 × 10-6 ounces) per sample can be obtained with a standard deviation of ±0.1 mg (±3.5 × 10-6 ounces).
Rationale
Content
The document has been significantly updated to make it reflect current practices, and two new appendices have been introduced to detail procedures that are referenced in the document.
Meta TagsDetails
DOI
https://doi.org/10.4271/ARP785B
Pages
12
Citation
SAE International Recommended Practice, Procedure for the Determination of Particulate Contamination in Hydraulic Fluids by the Control Filter Gravimetric Procedure, SAE Standard ARP785B, Revised December 2020, Reaffirmed January 2002, Issued February 1963, https://doi.org/10.4271/ARP785B.
Additional Details
Publisher
Published
Dec 3, 2020
Product Code
ARP785B
Content Type
Recommended Practice
Status
Revised
Language
English

Revisions