ARP743B Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method

Revised

03/01/2001

Features
Issuing Committee
Scope
Content
This SAE Aerospace Recommended Practice (ARP) describes two procedures for sampling particles in dust controlled spaces. One procedure covers airborne dust above 5 μm. The other (and newly added procedure) covers particles of 25 μm and larger that “fall out” of the environment onto surfaces. In each case the particles are sized in the longest dimension and counted. Airborne particles are reported as particles per cubic meter (cubic foot) whereas particles collected in fall out samples are reported as particles per 0.1 square meter (square foot). This document includes English units in parentheses as referenced information to the SI units where meaningful.
These procedures may also be used for environmental analysis where the quality of the particles by visual or chemical analysis is intended.
Meta TagsDetails
DOI
https://doi.org/10.4271/ARP743B
Pages
10
Citation
SAE International Recommended Practice, Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method, SAE Standard ARP743B, Revised March 2001, Issued July 1966, https://doi.org/10.4271/ARP743B.
Additional Details
Publisher
Published
Mar 1, 2001
Product Code
ARP743B
Content Type
Recommended Practice
Status
Revised
Language
English