Content
This document presents standard methods to evaluate the common mode and differential mode insertion loss of passive electromagnetic interference power line filters from 10 kHz through 10 GHz. Insertion loss test methods for both quality assurance and performance prediction purposes are described. The performance prediction tests are selected to more closely approximate operating impedances. They are not intended to be inclusive or to represent worst case conditions. However, the methodology of this document can be used to determine the performance in an arbitrary impedance circuit.
Rationale
Content
This test uses line impedance stabilization networks (LISN’s) to present more realistic source and load impedances than the 50 Ω resistive terminations of MIL-STD-220A. The LISN’s are networks with 50 microhenries of series inductance, per Figure 2 of MIL-STD-462D.
Meta TagsDetails
DOI
https://doi.org/10.4271/ARP4244
Pages
1
Citation
SAE International Recommended Practice, Recommended Insertion Loss Test Methods for EMI Power Line Filters, SAE Standard ARP4244, Reaffirmed August 2004, Issued March 1998, https://doi.org/10.4271/ARP4244.