Thermal Effectiveness of Sleeve/Tubing/Tape Insulation

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2302_201703
  • Current
Published 2017-03-15 by SAE International in United States
This procedure measures the resistance to radiant heat flow of insulating materials in sleeve, tubing or tape (collectively referred to as “sleeve”) form. The sleeve’s effectiveness (SE) is determined by measuring the difference in surface temperature of a flat black, single-diameter ceramic cylinder with and without the standard diameter sleeve at the specified temperature, position, and distance from the radiant heat source.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Recommended Testing Methods for Physical Protection of Wiring Harnesses

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2192_201606
  • Current
Published 2016-06-03 by SAE International in United States
This SAE Recommended Practice describes the recommended methods for testing flexible harness coverings for use on ground vehicle electrical distribution systems. This Recommended Practice shall apply to all tapes, extruded tube and textile tube.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Recommended Testing Methods for Physical Protection of Wiring Harnesses

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2192_201503
  • Historical
Published 2015-03-05 by SAE International in United States
This SAE Recommended Practice describes the recommended methods for testing flexible harness coverings for use on ground vehicle electrical distribution systems. This Recommended Practice shall apply to all tapes, extruded tube and textile tube.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Thermal Effectiveness of Sleeve Insulation

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2302_201102
  • Historical
Published 2011-02-21 by SAE International in United States
This procedure measures the resistance to radiant heat flow of insulating materials in sleeve form. The sleeve’s effectiveness (SE) is determined by measuring the difference in surface temperature of a flat black, single-diameter ceramic cylinder with and without the standard diameter sleeve at the specified temperature, position, and distance from the radiant heat source.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Thermal Containment Efficiency of Sleeve Materials

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2495_201102
  • Current
Published 2011-02-21 by SAE International in United States
This SAE Standard measures the percent thermal efficiency of materials in sleeve form used to contain heat or insulate around a hot component. The percent thermal efficiency (%TE) is determined by measuring the power difference expended by the heat source (cartridge heater) with and without the test sleeve at the specified temperature. See SAE J2302 to measure radiant heat flow of sleeves.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Recommended Testing Methods for Physical Protection of Wiring Harnesses

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2192_201006
  • Historical
Published 2010-06-28 by SAE International in United States
This SAE Recommended Practice describes the recommended methods for testing flexible harness coverings for use on ground vehicle electrical distribution systems. This Recommended Practice shall apply to all tapes, extruded tube and textile tube.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Thermal Containment Efficiency of Sleeve Materials

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2495_200809
  • Historical
Published 2008-09-04 by SAE International in United States
This SAE Standard measures the percent thermal efficiency of materials in sleeve form used to contain heat or insulate around a hot component. The percent thermal efficiency (%TE) is determined by measuring the power difference expended by the heat source (cartridge heater) with and without the test sleeve at the specified temperature. See SAE J2302 to measure radiant heat flow of sleeves.
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Thermal Effectiveness of Sleeve Insulation

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2302_200809
  • Historical
Published 2008-09-04 by SAE International in United States
This procedure measures the resistance to radiant heat flow of insulating materials in sleeve form. The sleeve's effectiveness (S{sub}E) is determined by measuring the difference in surface temperature of a flat black, single- diameter ceramic cylinder with and without the standard diameter sleeve at the specified temperature, position, and distance from the radiant heat source.
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Recommended Testing Methods for Physical Protection of Wiring Harnesses

Harness Covering Standards Committee
  • Ground Vehicle Standard
  • J2192_200505
  • Historical
Published 2005-05-19 by SAE International in United States
This SAE Recommended Practice describes the recommended methods for testing flexible harness coverings for use on gnround vehicle electrical distribution systems. This Recommended Practice shall apply to all tapes, extruded tube and textile tube.