Search
Advanced Search
of the following are true
(
)

Results

Items (211,878)
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck 12 VDC battery and electrical architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Truck and Bus Electrical Systems Committee
This SAE Recommended Practice covers passive torque biasing axle and center differentials used in passenger car and light truck applications. Differentials are of the bevel gear, helical gear, and planetary types, although other configurations are possible.
Drivetrain Standards Committee
This material type has resistance to hot air, but generally has poor resistance to fuels and lubricants, but usage is not limited to such applications. Each application should be considered separately. This material type has a typical service temperature range of -85 to 500 °F (-65 to 260 °C). The operating temperature range of the material is a general temperature range, but the presence of particular fluids and design parameters may modify this range. Recommendations on the material selection are based on available technical data and are offered as suggestions only. Each user should make his own tests to determine the suitability for his own particular use.
A-6C2 Seals Committee
This specification provides dimensional standards for crimp type contact wire barrel design and is a replacement for MS3190. Some wire barrel designs may exist in AS39029 but are not considered approved for future use, therefore, will not appear in this specification. The crimp barrel sizes listed in this document have been standardized in AS39029 and AS22520 specifications, tools and contacts are available to support these listed sizes. These crimp barrel requirements shall be used for any contact, regardless of whether it is a standard or non-standard contact configuration. The specification lists details for three types of wire barrels: A, B, and C. Wire barrel type A is not recommended for new design. Table 4 lists each AS39029 detail sheet wire barrel type.
AE-8C1 Connectors Committee
This SAE Standard describes the requirements of the linkage to attach implements or equipment to the front of agricultural wheeled tractors. This shall be a three-point linkage in association with a power lift. It applies to the categories defined in ISO 730/1.
Agricultural Tractor Standards Committee (ATSC)
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at −18 °C. A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 4 °C. The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.
Interior Climate Control Vehicle OEM Committee
This recommended practice provides minimum requirements for testing components or systems of the type which can be switched from one truck to another with relative ease; i.e., aerodynamic devices, clutch fans, radial tires, and the like. The test utilizes in-service fleet vehicles, operated over representative routes. The relative fuel effectiveness of the component or system under test is determined as a percentage improvement factor. This factor is calculated using the relative fuel usage of like vehicles operating with and without the specific component or system under evaluation. Accuracy capability employing this test technique is either ±1% or ±2%, depending upon the method of fuel measured. (See paragraph 7.4.)
Truck and Bus Aerodynamics and Fuel Economy Committee
This SAE Standard was prepared to assist manufacturers of tractors and implements in providing suitable means of transmitting power from the tractor power take-off to the Implement and satisfactory hitching of the implement to the tractor.
Agricultural Tractor Standards Committee (ATSC)
This SAE Standard covers sub-critically annealed or normalized electric resistance welded flash controlled single-wall high strength steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, double flaring, cold forming, welding and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path caused by the ID weld bead. Nominal reference working pressures for this tubing are listed in ISO 10763 for metric tubing and SAE J1065 for inch tubing. This specification also covers SAE J2613 Type-A tubing. The mechanical properties and performance requirements of standard SAE J2613 and SAE J2613 Type-A are the same. The designated differences of Type-A tubing do not imply that Type-A tubing is in anyway inferior to standard SAE J2613. The Type-A disignation is meant to address the unique manufacturing differences between sub-critically
Metallic Tubing Committee
This SAE Standard covers the mechanical and material requirements for eight property classes of steel, externally threaded metric fasteners in sizes M1.6 through M36, inclusive, and suitable for use in automotive and related applications.
Fasteners Committee
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Cable Standards Committee
The scope and purpose of the SAE Recommended Practice is to provide standards for the control and indication of parking brakes in hydraulic braked vehicles over 4540 kg (10000 lb) GVWR. This recommended practice pertains to automatic transmission applications and supplements the SAE J915 recommended practice. This recommended practice does not address parking brake system performance. Parking brake system performance, both static and dynamic conditions, is the responsibility of the OEM vehicle manufacturer or manufacturers that modify the vehicle by adding special vocational required equipment (such as but not limited to outriggers, cranes, etc.).
Truck and Bus Hydraulic Brake Committee
This Recommended Practice describes some basic design requirements and operational procedures associated with equipment for laboratory measurement of tire force and moment properties of the full range of passenger car tires. These properties must be known to establish the tire's contribution to vehicle dynamic performance. Many factors influence laboratory tire force and moment measurements. This Recommended Practice was compiled as a guide for equipment design and test operation so that data from different laboratories can be directly compared and applied to vehicle design and tire selection problems. It is recognized that laboratory measurements define performance in a controlled and idealized situation that may not correspond to conditions encountered in a vehicle's operating environment. Several decades of testing experience in different laboratories indicates, however, that these tests can provide a very useful bench mark for evaluation of tire performance. It is neither necessary
Highway Tire Committee
The scope of this document focuses on the tests required by EPA to validate the performance of the FTIR system following the section in the Code of Federal Regulations Part 1065 (40 CFR 1U.1065 and hereafter referred to as “EPA Part 1065”) on the guidelines and performance criteria for various regulated gases. This document focuses on the use of continuous emissions sampling for both engine and vehicle testing. Future addenda will be needed to cover bag and other sampling techniques. Gas components that do not currently have performance criteria but may soon be regulated are noted and EPA suggestions as to what should be required are applied. This will help ensure that the FTIR will be recognized as a valid and alternative tool for engine exhaust emissions testing. Components in engine exhaust that are specifically called out in this document include: carbon monoxide (CO), carbon dioxide (CO2), oxides of nitrogen (NO, NO2, and N2O), ammonia (NH3), methane (CH4), ethane (C2H6), and
Emissions Standards Committee
This terminology is intended to provide a common nomenclature for use in publishing road vehicle aerodynamics data and reports.
Road Vehicle Aerodynamics Forum Committee
This Recommended Practice defines a procedure, which will aid in assessing the contaminant wear characteristics of hydraulic components. This procedure utilizes a very high level of contaminant that permits an accelerated test to determine the wear effects of contamination in a relatively short period. This recommended practice utilizes the contamination sensitivity test circuit identified in SAE J2470.
Ship Fluid Systems Committee
Automotive and locomotive diesel fuels, in general, are derived from petroleum refinery products which are commonly referred to as middle distillates. Middle distillates represent products which have a higher boiling range than gasoline and are obtained from fractional distillation of the crude oil or from streams from other refining processes. Finished diesel fuels represent blends of middle distillates and may contain other blending components of substantially non-petroleum origin, such as biodiesel fuel blend stock, and/or middle distillates from non-traditional refining processes, such as gas-to-liquid processes. The properties of commercial distillate diesel fuels depend on the refinery practices employed and the nature of the crude oils from which they are derived. Thus, they may differ both with and within the region in which they are manufactured. Such fuels generally boil, at atmospheric pressure, over a range between 130 °C and 400 °C (approximately 270 °F to 750 °F). Their
Fuels and Lubricants TC 7 Fuels Committee
This document applies primarily to mobile cranes that lift loads by means of a drum and hoist line mechanism. It can be used to determine the hoist line speed and power of other hoist line mechanisms, if the load can be held constant and hoist line travel distance is sufficient for the accuracy of the line speed measurements prescribed. This recommended practice applies to all mechanical, hydraulic, and electric powered hoist mechanisms.
Cranes and Lifting Devices Committee
All carbon and alloy H-band steels are shown, along with their corresponding minimum and maximum hardenability limits, for which sufficient hardenability data have been established and for grades which use the standard end-quench test. As hardenability data are accumulated for other grades, this SAE Standard will be revised to include such grades.
Metals Technical Committee
Items per page: