Standardized Symbols for Electrical Circuit Diagrams

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2221_201905
  • Current
Published 2019-05-16 by SAE International in United States
This SAE Recommended Practice identifies graphic symbols used in electrical circuit diagrams. The symbols aid troubleshooting electrical systems.
Annotation icon
 

Heavy Duty Truck and Bus Electrical Circuit Performance Requirement for 12/24-Volt Electric Starter Motors

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J3053_201901
  • Current
Published 2019-01-31 by SAE International in United States
The scope of this SAE Recommended Practice is to describe a design standard to define the maximum recommended voltage drop for starting motor main circuits, as well as control system circuits, for 12- through 24-V starter systems.
Annotation icon
 

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2191_201901
  • Current
Published 2019-01-08 by SAE International in United States
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Datasets icon
Annotation icon
 

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2698_201810
  • Current
Published 2018-10-04 by SAE International in United States
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Datasets icon
Annotation icon
 

Combination 11 Conductors and 2 Pairs ECBS Cable

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2742_201806
  • Current
Published 2018-06-03 by SAE International in United States
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Datasets icon
Annotation icon
 

Accelerator Pedal Position Sensor for Use with Electronic Controls in Medium- and Heavy-Duty Vehicle Applications—Truck and Bus

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J1843_201805
  • Current
Published 2018-05-24 by SAE International in United States
The purpose of this SAE Recommended Practice is to provide a common electrical and mechanical interface specification that can be used to design electronic accelerator pedal position sensors and electronic control systems for use in medium- and heavy-duty vehicle applications.
Annotation icon
 

Truck Tractor Power Output for Trailer ABS

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2247_201805
  • Current
Published 2018-05-24 by SAE International in United States
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Datasets icon
Annotation icon
 

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2691_201804
  • Current
Published 2018-04-15 by SAE International in United States
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Datasets icon
Annotation icon
 

Coiled Electrical Cable - Truck and Bus

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2222_201802
  • Current
Published 2018-02-15 by SAE International in United States
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Datasets icon
Annotation icon
 

Seven Conductor Cable for ABS Power - Truck and Bus

Truck and Bus Electrical Systems Committee
  • Ground Vehicle Standard
  • J2394_201712
  • Current
Published 2017-12-20 by SAE International in United States
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Datasets icon