Your Selections

TEAAE8D
Show Only

Collections

File Formats

Content Types

Dates

Sectors

Topics

Publishers

Committees

Committee Codes

   This content is not included in your SAE MOBILUS subscription, or you are not logged in.
new

WIRE, ELECTRIC, CROSSLINKED POLYALKENE INSULATED, SILVER-COATED HIGH STRENGTH COPPER ALLOY, LIGHT WEIGHT, 600-VOLT, 150 °C

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS81044/13B
  • Current
Published 2019-08-29 by SAE International in United States

Scope is unavailable.

   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarlyene Insulated, Copper or Copper Alloy

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS81044B
  • Current
Published 2019-07-08 by SAE International in United States
AS81044 covers single conductor electric wires made as specified in the applicable detail specification with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the detail specification.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Cable, Power, Electrical, Portable General Specification For

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS5756B
  • Current
Published 2019-06-07 by SAE International in United States
This specification covers 600 V heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations). The AS5756 insulation system has been used in aerospace ground power applications using 115/200 V (phase to neutral) at 400 Hz AC. Verification of the suitability of this product for use in other electrical system configurations (600 V, etc.) is the responsibility of the user.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

CABLE, LIGHTWEIGHT OPTIMIZED HIGH SPEED DATA QUAD, 110 OHM, 200 °C

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS6070/8A
  • Current
Published 2019-05-07 by SAE International in United States
No Abstract Available.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification for

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS23053A
  • Current
Published 2019-04-08 by SAE International in United States
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYVINYL CHLORIDE, SEMI RIGID, CROSSLINKED AND NON-CROSSLINKED

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS23053/3
  • Current
Published 2019-04-08 by SAE International in United States
No Abstract Available.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLAME RETARDED, MODIFIED POLYOLEFIN, FLEXIBLE, CROSSLINKED

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS23053/17
  • Current
Published 2019-04-08 by SAE International in United States
No Abstract Available.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYVINYL CHLORIDE, SEMI RIGID, CROSSLINKED AND NON-CROSSLINKED

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS23053/2
  • Current
Published 2019-04-08 by SAE International in United States
No Abstract Available.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

WIRE, ELECTRIC, FLUOROPOLYMER-INSULATED, EXTRUDED TFE, POLYIMIDE COATED, NICKEL-COATED HIGH STRENGTH COPPER ALLOY CONDUCTOR, 600-VOLT, ROHS

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS22759/31B
  • Current
Published 2019-04-05 by SAE International in United States
No Abstract Available.
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

WIRE, ELECTRIC, FLUOROPOLYMER-INSULATED EXTRUDED TFE, POLYIMIDE COATED, SILVER-COATED HIGH STRENGTH COPPER ALLOY CONDUCTOR, 600-VOLT, ROHS

AE-8D Wire and Cable Committee
  • Aerospace Standard
  • AS22759/30B
  • Current
Published 2019-04-05 by SAE International in United States
No Abstract Available.
This content contains downloadable datasets
Annotation ability available