Thermal, Hydraulic and Drainable Performances of Slant Louver Fin for Automobile Applications
2012-01-1218
04/16/2012
- Event
- Content
- The purpose of the present study was to investigate the characteristics of pressure drop, heat transfer rate and drainability for a brazed aluminum heat exchanger. Scaled-up models with standard and 30 degree-slant louver fins were made, and their thermal and hydraulic performances were tested in a wind tunnel. The drainability of the fins was compared by measuring the retained water after dipping the heat exchangers. The slant louver fin showed a 13% higher pressure drop and 2% lower heat transfer coefficient than the standard louver fin. It also retained about half of the water that the standard louver fin did.
- Pages
- 5
- Citation
- Kang, H., and Kim, K., "Thermal, Hydraulic and Drainable Performances of Slant Louver Fin for Automobile Applications," SAE Technical Paper 2012-01-1218, 2012, https://doi.org/10.4271/2012-01-1218.