This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Relative Thermal Life and Temperature Index for Insulated Electric Wire
- Aerospace Standard
- AS4851A
- Reaffirmed
Downloadable datasets available
Annotation ability available
Sector:
Issuing Committee:
Language:
English
Scope
This test method provides performance data on candidate insulation systems as a function of time and temperature. These data give engineering information on the wire insulation candidate relative to the performance of materials already in use with a backlog of experience. These tests expose candidate insulation systems to a wide range of temperatures for short and long periods of time, while measuring the degradation of its physical properties. For aerospace use, end-point proof tests include mandrel bend, water soak, and dielectric integrity.
Rationale
AS4851A has been reaffirmed to comply with the SAE Five-Year Review policy.
Recommended Content
Topic
Data Sets - Support Documents
Title | Description | Download |
---|---|---|
Unnamed Dataset 1 | ||
TABLE 1 | Model Data Table of Observed Thermal Life Test Data Time to Failure, in Hours, at Temperatures T , T , T , and T | |
TABLE A1 | Student T Statistics for 2 Sided Tests | |
TABLE B1 | Simulated Observed Thermal Life Test Data-Hours of Exposure to Failure | |
TABLE B2 | Observed Time to Failure | |
TABLE B3 | Log-Average Life | |
TABLE B4 | Predicted Life | |
Unnamed Dataset 8 | ||
Unnamed Dataset 9 | ||
Unnamed Dataset 10 | ||
Unnamed Dataset 11 | ||
Unnamed Dataset 12 | ||
Unnamed Dataset 13 |
Issuing Committee
AE-8D Wire and Cable Committee
SAE Subcommittee AE-8D Wire & Cable, shall be associated with those activities directed by the parent SAE Aerospace Council, the SAE Aerospace Electronics & Electrical System Division, and the SAE AE-8 Aerospace Electrical/Electronic Distribution Systems Committee, for the development and application of wires and cables and associated hardware standards and specifications.
Reference
Number | Title |
---|---|
ASTMD3032 | This document is not part of the subscrption. |
IEEENo.101 | This document is not part of the subscrption. |
IEEENo.98 | This document is not part of the subscrption. |
* Redlines comparisons are available for those standards
listed in the Revision History that contain a radio button. A
redline comparison of the current version against a revision is
accomplished by selecting the radio button next to the standard and
then selecting 'compare'. At this time, Redline versions only exist
for some AMS standards. SAE will continue to add redline versioning
with ongoing updates to SAE MOBILUS.