Metrology System for a Large, Somewhat Flexible Telescope

  • Magazine Article
  • TBMG-10830
Published January 01, 2009 by Tech Briefs Media Group in United States
Sector:
Language:
  • English

A proposed metrology system would be incorporated into a proposed telescope that would include focusing optics on a rigid bench connected via a deploy- able mast to another rigid bench holding a focal-plane array of photon counting photodetectors. Deformations of the deployable mast would give rise to optical misalignments that would alter the directions (and, hence, locations) of incidence of photons on the focal plane. The metrology system would measure the relative displacement of the focusing-optics bench and the focal-plane array bench. The measurement data would be used in post-processing of the digitized photodetector outputs to compensate for the mast-deformation-induced changes in the locations of incidence of photons on the focal plane, thereby making it possible to determine the original directions of incidence of photons with greater accuracy.