Connectors, Electrical, Reverse Bayonet, General Specification for
- Aerospace Standard
- AS95234B
- Revised
Downloadable datasets available
Annotation ability available
Sector:
Issuing Committee:
Language:
English
Scope
AS95234 includes reverse bayonet coupling, high current electrical connectors that are water tight and principally used in shipboard, ground vehicles and ground support equipment applications at serve voltages from 200 to 3000 Vrms and temperatures between -55 °C and +125 °C (-67 °F and +257 °F). See 6.1.5 for applications details. For aerospace application connectors, refer to AS50881.
Rationale
Revision is required to change dimensions in Figure A2; add dimension F values to Table A2; change dimension G and H values in Table A1; change G dimensions in Table A2; remove "class 1" from 3.3.3 description of black anodized finish; change minimum axial force in Table 6 and add note under Table A2; correct reference in 1.2.1; update references in 2.1, 2.2, 2.4, 2.7, 3.2. 3.3, 3.4 and 3.7; add EIA procedures in 2.5; correct appendix reference in 3.4.6.2; correct reference in 3.4.10 and 3.5.16.1; delete AS85049/31 reference from 3.5.16.2; correct reference in Tables 8 and 10; correct metric number in 4.7.8 and 4.7.18; correct EIA reference in 4.7.17; correct references in 4.7.18.1b; correct references in 4.7.24.2 and 6.1.3.2; correct metric numbers in Tables A1, A8, and C1; and correct references in 3.3.2.
Topic
Data Sets - Support Documents
Title | Description | Download |
---|---|---|
Unnamed Dataset 1 | ||
Unnamed Dataset 2 | ||
Unnamed Dataset 3 | ||
Unnamed Dataset 4 | ||
Unnamed Dataset 5 | ||
Table 1 | Wire range accommodations | |
Table 2 | Solder contact resistance with tin and silver plated wire | |
Table 3 | Solder contact engagement and separation forces | |
Table 4 | Contact insertion and removal forces | |
Table 5 | RFI leakage attenuation | |
Table 6 | RFI spring finger force | |
Table 7 | Qualifying activity test requirements | |
Unnamed Dataset 13 | ||
Unnamed Dataset 14 | ||
Table 8 | Supplier test requirements | |
Table 8 | Supplier test requirements | |
Table 8 | Supplier test requirements | |
Table 8 | Supplier test requirements | |
Table 9 | Qualification by similarity | |
Table 10 | Group A inspection | |
Table 11 | Contact retention axial loads | |
Table 12 | Dielectric withstanding test voltages | |
Table 13 | Test voltages after humidity | |
Table 14 | Insert retention test pressures | |
Table 15 | External bending moment | |
Table 16 | Working voltages | |
Table A1 | and dimensions in inches (millimeters) | |
Table A1 | and dimensions (continued) | |
Table A1 | and dimensions (continued) | |
Table A2 | and dimensions in inches (millimeters) | |
Table A2 | and dimensions in inches (millimeters) (continued) | |
Table A3 | dimensions in inches (millimeters) | |
Table A4 | Metric equivalents for through | |
Table A5 | dimensions (metric equivalents) | |
Table A6 | dimensions in inches (millimeters) | |
Table A7 | dimensions | |
Table A8 | dimensions | |
Table A9 | AS85049 connector accessories recommended for AS95234 connectors | |
Table A9 | AS85049 connector accessories recommended for AS95234 connectors (continued) | |
Table B1 | Minimum mechanical spacing and creepage | |
Table B2 | Insert arrangements listed by shell size | |
Table B2 | Insert arrangements listed by shell size (continued) | |
Table B2 | Insert arrangements listed by shell size (continued) | |
Table B2 | Insert arrangements listed by shell size (continued) | |
Table B2 | Insert arrangements listed by shell size (continued) | |
Table B2 | Insert arrangements listed by shell size (continued) | |
Table B2 | Insert arrangements listed by shell size (continued) | |
Table B3 | Contact designation | |
Table C1 | Solder contact dimensions in inches (millimeters) |
Issuing Committee
SAE Subcommittee AE-8C1, Connectors, shall be associated with those activities directed by the parent SAE Aerospace Council and the SAE Aerospace Electronics and Electrical Distribution Systems Committee, for the development and application of electrical optical connector and associated hardware standards and specifications. SAE Subcommittee shall also serve the needs of the Navy, Army, and Air Force through the establishment and maintenance of User Advisory Committees.
Reference
* Redlines comparisons are available for those standards
listed in the Revision History that contain a radio button. A
redline comparison of the current version against a revision is
accomplished by selecting the radio button next to the standard and
then selecting 'compare'. At this time, Redline versions only exist
for some AMS standards. SAE will continue to add redline versioning
with ongoing updates to SAE MOBILUS.