This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Conditions That Limit Oil Circulation in a Mobile Air-Conditioning System
Annotation ability available
Sector:
Language:
English
Abstract
An important design objective for an automotive air-conditioning system is ensuring sufficient oil return to the compressor. Maintaining proper lubrication of the compressor extends compressor life and thus minimizes warranty and consumer replacement costs.
An automotive air-conditioning test stand capable of monitoring transient system parameters was utilized. Real-time oil concentration data were obtained using an optical, oil-concentration sensor installed in the liquid line. The mass flow rate of the refrigerant-oil mixture and the evaporator superheat were varied with an electronic expansion valve. Steady-state oil concentration data are presented for both saturated and superheated evaporator exit conditions. Experimental oil concentration data taken during system startup and quasi-steady compressor-clutch-cycling conditions are also presented.
Steady-state results show that oil return rate is maximized by maintaining a two-phase condition at the evaporator exit. Doing so prevents the accumulation of oil in the evaporator and thus provides better lubrication of the compressor. The observed behavior can be explained in terms of the viscosity of the refrigerant-oil film. Analysis shows that the viscosity of the oil film in a superheated section of the evaporator is quite high creating a significant resistance to oil flow. Adding only a small amount of liquid refrigerant to the film reduces the viscosity substantially thus allowing the oil to more freely return to the compressor.
Compressor start-up and quasi-steady tests reveal a significant peak in oil concentration approximately 10 s after clutch engagement. This time delay corresponds to the transport time between the compressor and the oil concentration sensor as calculated by a numerical model of the mobile air-conditioning system. Thus, the data suggest that a significant amount of oil is ejected when the compressor is first started although additional studies are needed to confirm and refine this conclusion.
Recommended Content
Technical Paper | e-Thermal: Automobile Air-Conditioning Module |
Technical Paper | A Study of the Auxiliary Belt Drive System for Actual Fuel Saving |
Technical Paper | Methods for Detection of Lubrication Failure Applied to a Swashplate Compressor |
Authors
- Eric Wandell - Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign
- William E. Dunn - Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign
- Norman Miller - Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign
- Ty Newell - Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign
Topic
Citation
Wandell, E., Dunn, W., Miller, N., and Newell, T., "Conditions That Limit Oil Circulation in a Mobile Air-Conditioning System," SAE Technical Paper 980286, 1998, https://doi.org/10.4271/980286.Also In
References
- Baustian, J. J. Bergles A. E. Pate M. B. 1986 “Properties of Oil-Refrigerant Liquid Mixtures with Applications to Oil Concentration Measurement: Part I - Thermophysical and Transport Properties.” ASHRAE Transactions 55 73
- Baustian, J. J. Bergles A. E. Pate M. B. 1986 “Properties of Oil-Refrigerant Liquid Mixtures with Applications to Oil Concentration Measurement: Part II - Electrical and Optical Properties.” ASHRAE Transactions 74 92
- Baustian, J. J. Pate M. B. Bergles A. E. 1988 “Measuring the Concentration of a Flowing Oil-Refrigerant Mixture with a Vibrating U-Tube Densiometer.” ASHRAE Transactions 94 571 587
- Baustian, J. J. Pate M. B. Bergles A. E. 1988 “Measuring the Concentration of a Flowing Oil-Refrigerant Mixture with a Bypass Viscometer.” ASHRAE Transactions 94 588 601
- Baustian, J. J. Pate M. B. Bergles A. E. 1988 “Measuring the Concentration of a Flowing Oil-Refrigerant with an Acoustic Velocity Sensor.” ASHRAE Transactions 94 602 615
- Cavestri, R. C. Menning M. Munk J. 1994 “Solubility, Viscosity, and Density Measurements of Refrigerant-Lubricant Mixtures - Part II: Polyalkylene Glycols with R134a.” ASHRAE Transactions 231 238
- Collins, C. D. Miller N. R. 1996 Experimental Study of Mobile Air Conditioning System Transient Behavior Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign
- Newell, T. A. 1996 “ In Situ Refractometry for Concentration Measurements in Refrigeration Systems.” HVAC&R Research 2 3 247 256
- Rubio-Quero, J. E. Dunn W. E. Miller N. R. 1995 A Facility for Transient Testing of Mobile Air Conditioning Systems Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign
- Schlager, L. M. Pate M. B. Bergles A. E. 1990 “Oil Quantity Measurements in Smooth and Micro-Fin Tubes During Evaporation and Condensation.” ASHRAE Transactions 96 465 469
- Weston, P. G. Dunn W. E. Miller N. R. 1996 Design and Construction of a Mobile Air Conditioning Test Facility for Transient Studies Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign
- Wandell, E. W. Dunn W. E. Miller N. R. 1997 Experimental Investigation of Mobile Air Conditioning System Control for Improved Compressor Reliability Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign
- Whitchurch, M. R. Dunn W. E. Miller N. R. 1997 Humidity Effects in Mobile Air-Conditioning Systems Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign