Space environmental control systems must control cabin temperature and humidity. This can be achieved by transferring the heat load to a circulating coolant, condensing the humidity, and separating the condensate from the air stream. In addition, environmental control systems may be required to remove particulate matter from the air stream. An assembly comprised of a filter, a condensing heat exchanger, a thermal control valve, and a liquid carryover sensor, is used to achieve all these requirements.
A condensing heat exchanger and filter assembly (CHXFA) is being developed and manufactured by SECAN/AlliedSignal under a contract from Dornier Daimler-Benz as part of a European Space Agency program. The CHXFA is part of the environmental control system of the Columbus Orbital Facility (COF), the European laboratory module of the International Space Station (ISS).
The CHXFA contains a filter to remove particulates from the air stream, and a differential pressure sensor to monitor filter pressure drop. The condensing heat exchanger reduces the air temperature and the humidity level. Efficient air-water separation is achieved by a combination of a hydrophilic coating on the heat exchanger air flow passages and a water removal section. A thermal control valve regulates the temperature of the outlet air. A sensor is incorporated in the outlet line to detect liquid carryover in the air stream.
This paper gives an overview of the condensing heat exchanger assembly developed for the Columbus Orbital Facility.
Authors
- Hélène Fourquet - Société D'études et de Constructions Aéro-Navales
- Pierre Carpentier - Société D'études et de Constructions Aéro-Navales
- André Rolland - Société D'études et de Constructions Aéro-Navales
- Claude Martin - Société D'études et de Constructions Aéro-Navales
- Helen Pickup - AlliedSignal Aerospace
- Susan Rose - AlliedSignal Aerospace
Topic
Citation
Fourquet, H., Carpentier, P., Rolland, A., Martin, C. et al., "Columbus Orbital Facility Condensing Heat Exchanger and Filter Assembly," SAE Technical Paper 972409, 1997, https://doi.org/10.4271/972409.Also In
References
- Liu, B. Y. H. Rubow K. L. McMurray P. H. Kotz T. J. Russo D. SAE Technical Paper 911476 1991
- Goodman, J. R. Villarreal L. J. SAE Technical Paper 921345 1992
- Rodgers, E. NASA TM-86563 1986
- Pickup, H. Zhou S. J. Proceedings of the 27th International Conference on Environmental Systems July 14 17 1997
- Eilender, A. Opperman R. Handbook of Coating Additives 177 224 1987 Calbo L. Marcel Dekker, Inc.
- McConville, K. Lavenir M. Seurig R. Barnes, J. Proceedings of the 27th International Conference on Environmental Systems July 14 17 1997