This paper describes the system modification through the improvement of pulse air penetration into the DPF cell channels in respect to the development of a wall-flow type diesel particulate filter ( DPF ) system with reverse pulse air regeneration for diesel vehicles.
In this system, regeneration becomes more difficult with low exhaust gas temperatures and increased DPF volume. The pressure increase in the DPF cell channels was monitored as a parameter of pulse air penetration when reverse pulse air was injected into the DPF. By maximizing the pressure increase, the pulse air injection system was modified. The modification includes various changes in the air pipe arrangement and the air injecting time. The ratio of the length to the diameter of the DPF was also evaluated in relation to the regeneration efficiency.
In this study, the high aspect ratio, i.e. small diameter and long DPF, showed better regeneration efficiency. The results of this study indicate that this system can be enlarged with the above modification despite low exhaust gas temperatures.
Recommended Content
Authors
Citation
Ichikawa, Y., Hattori, I., and Kasai, Y., "The Regeneration Efficiency Improvement of the Reverse Pulse Air Regenerating DPF System," SAE Technical Paper 960127, 1996, https://doi.org/10.4271/960127.Also In
References
- Kojetin P. et al. “Production Experience of a Ceramic Wall Flow Electric Regeneration Diesel Particulate Trap” SAE 930129 1993
- Balzotti A. et al. “Italian City Buses with Particulates Traps” SAE 900114 1990
- Suto H. et al. “Evaluation of Diesel Particulate Filter Systems for City Buses” SAE 910334 1991
- Kumagai Y. et al. “A Particulate Trap System Using Electric Heating Regeneration for Small Trucks” SAE 920141 1992
- Kitagawa J. et al. “Improvement of Pore Size Distribution of Wall Flow Type Diesel Particulate Filter” SAE 920144 1992
- Igarashi T. et al. “Development of Diesel Particulate Trap Systems for City Buses” SAE 910138 1991
- Matsunuma A. et al. “Status of Particulate Trap System for a Heavy Duty Diesel Truck” SAE 910132 1991
- Takesa K. et al. “Development of Particulate Trap System with Cross Flow Ceramic Filter and Reverse Cleaning Regeneration” SAE 910326 1991
- Kim S.H. et al. “Design of a Diesel Particulate Trap-Incinerator with Simultaneous Filtration and Compressed Air Regeneration ( CAR )” SAE 930367 1993
- Mehta S. et al. “On-Road Testing of a Reverse Air-Flow Cleaning, Soot-Oxidizing Diesel Particulate Trap System” SAE 930368 1993
- Levendis A. et al. “Evaluation of a Self-Cleaning Particulate Control System for Diesel Engines” SAE 910333 1991
- Uchiyama T. et al. “Development of Particulate Trap System with Cross Flow Ceramic Filter and Reverse Flow Cleaning Regeneration 2” SAE 940463 1994
- Yamada T. et al. “Development of Wall-Flow Type Diesel Particulate Filter System with Reverse Pulse Air Regeneration” SAE 940237 1994
- Ichikawa Y. et al. “Development of Wall-Flow Type Diesel Particulate Filter System with Efficient Reverse Pulse Air Regeneration” SAE 950735 1995