Abstract
Emergency Diesel Generator (EDG) reliability has long been a major concern in the nuclear power industry. This issue has been evaluated and addressed by the Nuclear Regulatory Commission (NRC) through various regulatory guidance papers. A recent aspect of these efforts allows utilities to remove accelerated EDG testing from their plant Technical Specifications provided they implement the Maintenance Rule for the EDG System.
This paper discusses the key elements and processes involved in developing a program to monitor the effectiveness of EDG maintenance, or in other words, implement the Maintenance Rule for the EDG system. This process is being used in early implementation of the Maintenance Rule for three nuclear generating stations and incorporates guidance provided to the nuclear industry in Regulatory Guide (RG) 1.160, “Monitoring the Effectiveness of Maintenance at Nuclear Power Plants,” [1] and NUMARC 93-01 “Industry Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants,” dated May 1993 [2]. This approach to implementing the Maintenance Rule for EDGs is considered an “alternative approach” due to certain exceptions taken to the regulatory interpretation of industry guidelines, also discussed in this paper.
Recommended Content
Authors
Topic
Citation
O'Brien, T. and Bronson, T., "Maintenance Rule Implementation for the Emergency Diesel Generator System," SAE Technical Paper 952142, 1995, https://doi.org/10.4271/952142.Also In
References
- Regulatory Guide 1.160 Monitoring the Effectiveness of Maintenance at Nuclear Power Plants
- Industry Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants
- Resolution of Generic Safety Issue B-56, ‘Diesel Generator Reliability’
- Generic Letter 94-01 Removal of Accelerated Testing and Special Reporting Requirements for Emergency Diesel Generators
- Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants
- Regulatory Guide 1.9 Selection, Design, Qualification, and Testing of Emergency Diesel Units Used as Class 1E Onsite Electric Power Systems at Nuclear Power Plants
- Guidelines and Technical Bases for NUMARC Initiatives Addressing Station Blackout at Light Water Reactors
- Generic Letter 84-15 Proposed Staff Actions to Improve and Maintain Diesel Generator Reliability