An Extravehicular Mobility Unit (EMU) Portable Life Support Subsystem (PLSS) has among its primary functions requirements to remove metabolically generated heat and respiratory byproducts to maintain an atmosphere which is both physiologically safe and comfortable for the Extravehicular Activity (EVA) crew person. The EMU thermal control system interacts with the crew member through the Liquid Cooling and Ventilation Garment (LCVG), which circulates the ventilation gas to remove carbon dioxide, humidity, and trace contaminants, and the cooling water to remove metabolically produced heat. To maintain thermal comfort, the crew member may vary the LCVG inlet water temperature. The thermal interaction between the EMU and the crew member is very complex and highly dependent upon the individual crew member's cooling preferences and the exterior environment. Changes in metabolic activity will create EMU thermal cooling transients which affect both crew member cooling preferences and vent loop heat balances. In particular, the interactions between the person, the water cooling system, and the ventilation gas circulation system have a substantial impact on the evaporative heat transfer. Under certain transient conditions, condensation of metabolic water may occur. Under other conditions, this water reevaporates, resulting in some cases in transient evaporative cooling effects for the crew person.
This study defines the effects that the ventilation loop/LCVG operation has on overall crew cooling and total EMU heat balances, with special focus on EMU metabolic water removal. The results of a vacuum test series conducted at the Johnson Space Center using the current configuration EMU (closed loop with human test subjects) are presented. Operational differences as well as thermal physiological differences between individual crew members were evaluated to measure the impacts on EMU performance.
Recommended Content
Technical Paper | Further Testing of an Amine-Based Pressure-Swing System for Carbon Dioxide and Humidity Control |
Aerospace Standard | Testing of Oxygen Equipment |
Technical Paper | Effect of Geometry Variation in a Polymer Electrolyte Membrane Fuel Cell |
Authors
Citation
Thomas, G., Schneider, S., Keilich, M., and Conger, B., "Crew Member/Extravehicular Mobility Unit Thermal Interactions Affecting Cooling Preferences and Metabolic Water Removal," SAE Technical Paper 951637, 1995, https://doi.org/10.4271/951637.Also In
References
- Waligora, J. M. Kumar K. V. Dr. “Use of Liquid Cooling in the Launch and Entry Suit - Phase II,” SD5-94-JMW1, Space Biomedical Research Institute of NASA-JSC February 1994
- Cooney, D. O. Biomedical Engineering Principles, An Introduction to Fluid, Heat, and Mass Transport Processes Marcel Dekker, Inc. New York, NY 1976
- Bue, G. C. “Computer Program Documentation 41-Node Transient Metabolic Man Program,” LESC-27578, Lockheed Engineering and Sciences Company October 1989
- Tepper, E. “RID No. EPC-217, Heat Leaks/Crew Comfort in Worst Environments,” Analysis 78-140 August 14 1978
- Tepper, E. “Revised PLSS Expendable Water Requirements,” Analysis 84-277 November 27 1984
- Parker, J. F., Jr. West Vita R. Bioastronautics Data Book , 2nd Edition NASA SP-3006 BioTechnology, Inc. 1973