Abstract
Santa Barbara Research Center is currently under contract from NASA Goddard Space Flight Center to design and build the MODerate resolution Imaging Spectroradiometer (MODIS) for launch in 1998 on the EOS-AM spacecraft. MODIS is a remote sensing instrument incorporating state-of-the-art multi-spectral imaging and calibration technology. Two cooled infrared (IR) focal planes and two room-temperature visible and near infrared focal planes are used to gather imaging data in 36 discrete spectral bands between 0.41 and 14.4 μm. A passive radiative cooler is employed to achieve a nominal IR focal plane operating temperature of 85K.
To meet mission objectives, band-to-band registration of ±0.2 pixel and radiometric calibration accuracy better than 1% within the thermal region and 5% within the reflectance region must be maintained over a five-year instrument design life. This places significant demands on the thermal design which must provide a stable operating environment with minimal temperature gradients and thermoelastic distortion. Advanced engineering materials including beryllium and graphite/epoxy are used extensively in the design along with various passive thermal control techniques to optimize performance.
This paper presents an overview of MODIS thermal control design features along with a summary of analytical performance predictions for the overall system and for thermally critical subsystems such as the passive cryogenic radiative cooler. Thermal engineering challenges are discussed along with corresponding design solutions.
Recommended Content
Technical Paper | Reinforced Plastics Design Rolls-Royce RB.162 Lift Engine |
Technical Paper | Origin and Development of Ablator for Space Shuttle External Tank |
Technical Paper | The Development of LED Marker Lamp |
Authors
Topic
Citation
Bortfeldt, P., "Thermal Control Design for the MODIS Instrument," SAE Technical Paper 941601, 1994, https://doi.org/10.4271/941601.Also In
References
- Hughes-SBRC “Thermal Math Model - Final Report,” January 1994
- Hughes-SBRC “Structural Thermal Optical Performance Model (STOP),” December 1993
- Pagano T.S. Durham R.M. “Moderate Resolution Imaging Spectroradiometer (MODIS),” SPIE proc. 1939 2 17 1993
- Thurlow P.E. Cline R.W. “Measurement of MODIS optics effective focal length, distortion and modulation transfer function,” SPIE proc. 1939 47 60 1993
- Pagano T.S. Young J.B. “MODIS radiometric accuracy and sensitivity modeling using the Radiometric Math Model (RMM),” SPIE proc. 1939 18 28 1993
- NASA Goddard Space Flight Center “Earth Observing System (EOS) Specification for the Moderate-Resolution Imaging Spectroradiometer - Nadir (MODIS-N),” October 1990
- NASA Goddard Space Flight Center “General Instrument Interface Specification, EOS-AM Project,” December 1 1992