This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Space Station ATCS Performance During Orbiter Berthing
Annotation ability available
Sector:
Language:
English
Abstract
This paper documents the Space Station Freedom (SSF) Active Thermal Control System (ATCS) performance during approach/departure, berthing, and deberthing operations. Recommended fixed radiator orientations and radiator orientations as a function of the (β angle were used for SSF flights MB5 through UF-1. Radiator rotation restrictions impacting ATCS performance included plume loads during proximity operations, minimum clearances from the Shuttle post-mating, visual cues required for mating and/or SSF remote manipulator system, attitude perturbations, number of Orbital Replacement Units (ORUs) deployed and thermal radiator rotation joint bending moment response.
Three thermal models (TEA, ALPHA and TAURUS) performed the analyses on the MB5 through UF-1 mission builds. The study was divided into three parts pertaining to approach/departure, berthing, and deberthing. First, with SSF positioned in the pure gravity gradient mode the best locked radiator position was determined as a function of β angle. In the second part, the models determined the SSF ATCS radiator heat rejection capabilities as a function of β angle, and vehicle roll, pitch and yaw changes during the entire berthing operation. During this phase, the radiators were allowed to rotate to maximize heat rejection during the day, and minimize it during night. Another berthing scenario analyzed allowed the radiators to rotate until Reaction Control System/Control Moment Gyros (RCS/CMG) handover, when they were commanded to maintain the position they last had prior to handover. During the deberthing maneuver, the radiators rotated to the minimum environment except when commanded to lock during orbits 3 and 4.
The hottest environment values were used, along with End-Of-Life (EOL) radiator panel properties to determine SSF ATCS performance during mating operations. In examining the radiator heat rejection scenarios during approach and berthing, the ATCS provided the heat rejection required at some β angles for the 35°F set point in MB5 through UF-1. However, the deberthing and departure operations failed to meet the heat rejection requirements unless the set point temperature was raised or other methods were used to alleviate the problem. These methods included lowering the heat rejection requirements by powering down the station or performing the operations on the dark side of the orbit.
Authors
Citation
Kantara, J. and Graf, J., "Space Station ATCS Performance During Orbiter Berthing," SAE Technical Paper 932201, 1993, https://doi.org/10.4271/932201.Also In
References
- “Critical SSF Stage Configuration for Berthing Analyses” MDSSC TM No. TM-5.23.07-175, WBS No. 5.23.07.6, Contract No. NAS9-17885 March 23 1992
- Berthing Panel Minutes April 16, 1992
- “Preliminary Investigation of SSF ATCS Performance During Berthing” Ewert M. Kantara J. May 5 1992
- “Space Station Freedom Pre integrated Truss MTC Flight Data Book” LESC-29894, Contract NAS9-17900 October 1991
- “Post PDR HRS Radiator Gamma Angle Plume Impingement Study” Qualls Dale Marquette Brian March 25 1992
- “Control/Structure Interaction During Space Station-SRMS-Orbiter Berthing” Engler J. Kilby M. Lin Y.C. Mapar J. Dynacs Houston May 7, 1992
- “MOD Flyaway Analysis Status” Stockdale Tim May 7 1992
- “ATCS Radiator Clearance and Rotation During Berthing” Dominick J. /NASA/JSC/EC211 April 10 1992
- “Integrated Operation Scenarios, MB-1 through MB-7 and UF-1” Johnson Lyndon B. Space Center/NASA Document No. SSJ 10590 February 1992
- FLUINT Model Andish Kambiz /LESC/C70, (713)333-7180
- “Integrated Thermal Resource Assessment for IOS,” Lee David June 24 1992