Flash radiography is used to study the internal processes of closed liquid metal combustion systems. Future projects with the combustors include placing small hollow spheres within the active bath to trace fluid flow and obtain spatial and temporal data. A ray tracing program which employs simplified Monte Carlo methods has been developed for use as a predicting tool for radiographic images produced during testing. A complex focal spot is characterized by either a monochromatic or polychromatic emission spectrum. The x-ray detection system is modeled by a planar detector having 100% efficiency. The code simulates the imaging of the small hollow spheres in the combustor for three dimensional localization from two dimensional projections. Still radiographic images of a mock combustor and a plane of cylindrical objects are used to compare edge detection and object location for real and simulated images.
Authors
Citation
Kodimer, K., Parnell, L., Nelson, R., and Papin, P., "Computer Simulations of Closed Liquid Metal Combustor Fluid Flow," SAE Technical Paper 929368, 1992, https://doi.org/10.4271/929368.Also In
References
- Parnell, L.A. Edmunds, D.G. Rogerson, DJ. “RTR Studies of Closed Liquid Metal Fuels” Paper No. AIAA-87-1808 AIAA/ASEE/ASME/SAE 23rd Joint Propulsion Conference San Diego, CA July 1987
- Whalen, D.J. Hollowell, D.E. Hendricks, J.S. “MCNP: Photon Benchmark Problems” Los Alamos National Laboratories Publication September 1991 2
- Samson, P.D. “Methods of Real-Time Data Acquisition from Molten-Metal-Combustion Vessels Using X-Ray Tracing Computer Simulations” San Diego State University Fall 1990 13 15
- Attix, F.H. Introduction To Radiological Physics and Radiation Dosimetry Wiley Sons New York 1986 39
- Veigele, W.J. “Photon Cross Sections From 0.1 KEV to 1 MEV For Elements Z = 1 to Z = 94” Atomic Data Tables 5 1 1973