This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Sodium Wick Pumping Experiments for a Vapor-Fed AMTEC System
Annotation ability available
Sector:
Language:
English
Abstract
In a vapor-fed Alkali Metal Thermal to Electric Converter (AMTEC), the sodium in the low pressure condenser (100 Pa) must be returned to the high pressure evaporator (104 to 105 Pa). Most current designs use an EM pump to recirculate the fluid, but a wick-pumped system offers several advantages. A wick-pumped system uses capillary forces to passively return liquid to the evaporator, and to distribute the liquid in the evaporator.
In a wick-pumped AMTEC cell, the increase in pressure occurs in the evaporator at the liquid/vapor interface due to surface tension forces. The liquid in the wick has a pressure of a few Pa, and a temperature near the reservoir temperature, so the liquid is superheated by several hundred degrees Celsius. In addition, pressure drops in the liquid return system can drop the liquid sodium pressure below zero, placing the sodium in tension. While sodium can tolerate large superheats before the initiation of nucleate boiling, this superheat may be so high that boiling could occur, blocking the wick with vapor.
A capillary pumping demonstrator was fabricated and tested to demonstrate a wick design that can return liquid sodium against the pressure difference between the low pressure condenser and the high pressure evaporator in the AMTEC cell. The demonstrator uses a sodium heat pipe, with a pressure and temperature difference between the evaporator and condenser maintained with a small orifice. The demonstrator successfully operated with the evaporator at 690°C (12,000 Pa), and the condenser at 380°C (40 Pa). The demonstrator was designed to operate with a negative liquid pressure in the liquid return line, and successfully sustained negative pressures (tensions) as low as -2430 Pa.
Recommended Content
Technical Paper | Design of a Variable-Conductance Vacuum Insulation |
Technical Paper | Development of a Versatile Rheocasting Technology |
Ground Vehicle Standard | Valve Guide Information Report |
Authors
Citation
Anderson, W., "Sodium Wick Pumping Experiments for a Vapor-Fed AMTEC System," SAE Technical Paper 929146, 1992, https://doi.org/10.4271/929146.Also In
References
- Bankston, C. P. “Alkali Metal Thermoelectric Conversion (AMTEC) Technology Status Review,” Space Nuclear Power Systems 1986 El-Genk M. S Hoover M. D Orbit Book Co. Malabar, FL 1987
- Cole, T. 1983 “Thermoelectric Energy Conversion with Solid Electrolytes,” Science 221 4614 915 920
- Crowley, C. J. “Condenser Design for AMTEC Power Conversion,” Proc., 25 th Annual IECEC 5 456 462 Boston, MA August 4-9 1991
- Foust, O. J. Sodium-NaK Engineering Handbook: Sodium Chemistry and Physical Properties 1. Gordon and Breach New York, New York 1972
- Levy, E. K. “Theoretical Investigation of Heat Pipes Operating at Low Vapor Pressures,” J. Engineering for Industry (Trans. ASME) 547 552 November 1968
- Miller, R. W. Flow Measurement Handbook McGraw Hill New York, New York 1983
- Sievers, R. K. Bankston C. P. 1988 “Radioisotope Powered Alkali Metal Thermoelectric Converter Design for Space Systems,” Proc., 23 rd IECEC 3 159 167 Denver, CO 159 167
- Sievers, R. K. Cooper, M. H. “Advanced AMTEC Design Options with Composite Electrolyte Membranes,” Proc., Seventh Symposium on Space Nuclear Power Systems 1. 239 244 Albuquerque, NM Jan. 7-10 1990