Abstract
The objective of the study was to document the thoracic deformation contours in a simulated frontal impact. Unembalmed human cadavers and the Hybrid III anthropomorphic manikins were tested. Data from the newly developed External Peripheral Instrument for Deformation Measurement (EPIDM) was used to derive deformation patterns at upper and lower thoracic levels. Deceleration sled tests were conducted on three-point belt restrained surrogates positioned in the driver's seat (no steering assembly) using a horizontal impact test sled at velocities of approximately 14.0 m/s. Lap and shoulder belt forces were recorded with seat belt transducers. The experimental protocol included a Hybrid III manikin experiment followed by the human cadaver test. Both surrogates were studied under similar input and instrumentation conditions, and identical data acquisition and analysis procedures were used.
All six testedcadavers demonstrated multiple bilateral rib fractures. In addition, clavicle and sternum fractures were found. In one case, lung and liver lacerations occurred in the region of rib fracture. The location, magnitude, and time of occurrence of the maximum chest deflection demonstrated differences between the two surrogates; the patterns of the thoracic deformation contour were also different. Regions of high local curvature/deformation were identified in the human cadaver tissue. Maximum chest deflections ranged from 2.7 to 13.0 cm at the upper level (ribs 2 - 4) and 2.5 to 12.3 cm at the lower level (ribs 6 - 8) in the cadaver. The corresponding chest deflections in the Hybrid III manikin ranged from 3.3 to 6.7 cm and 2.9 to 5.7 cm at the upper and lower levels, respectively. The deflections recordedusing the internal potentiometerranged from 2.7 to 4.0 cm in the manikin. It can be concluded that the human cadavers in these tests exhibit greater regional differences and are more compliant in their thoracic deformation characteristics than the Hybrid III anthropomorphic manikin.
Recommended Content
Authors
- Narayan Yoganandan - Department of Neurosurgery, Medical College of Wisconsin
- David Skrade - Department of Neurosurgery, Medical College of Wisconsin
- Frank A. Pintar
- John Reinartz - Department of Neurosurgery, Medical College of Wisconsin
- Anthony Sances - Department of Neurosurgery, Medical College of Wisconsin
Topic
Citation
Yoganandan, N., Skrade, D., Pintar, F., Reinartz, J. et al., "Thoracic Deformation Contours in a Frontal Impact," SAE Technical Paper 912891, 1991, https://doi.org/10.4271/912891.Also In
References
- The Abbreviated Injury Scale 1990 Revision American Association for the Advancement of Automotive Medicine 1990
- Backaitis SH St-Laurent A Chest deflection characteristics of volunteers and hybrid III dummies Proc 30th Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1986 157 166
- Bohlin N A statistical analysis of 28000 accident cases with emphasis on occupant restraint value Proc 11th Stapp Car Crash Cont Society of Automotive Engineers New York, NY 1967 455 478
- Cesari D Bouquet R Behaviour of human surrogates thorax under belt loading Proc 34th Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1990 pp 73 81
- Eppinger RH Prediction of thoracic injury using measurable experimental parameters Report 6th Intl Technical Conf on Experimental Safety Vehicles Natl Highway Traffic Safety Administration Washington, D.C. 1976 770 779
- Eppinger RH Augustyn K Robbins DH Development of a promising universal thoracic trauma prediction methodology Proc 22nd Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1978 209 268
- Eppinger RH On the development of a deformation measurement system and its application toward developing mechanically based indices Proc 33rd Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1989 21 28
- Hagedorn AV Eppinger RH Morgan RM Pritz HB Khaewpong N Application of a deformation measurement system to mechanical systems Intl Research Council on Biokinetics of Impact Berlin, Germany September 1991
- Katz E Grosch L Kassing L Chest compression response of a modified Hybrid III with different restraint systems Proc 31 st Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1987 245 249
- Matsuoka F Kumagai K Takahashi H Problem and improvement of Hybrid III dummy rib cage features Proc 7th Intl Technical Conf on Experimental Safety Vehicles U.S. Department of Transportation, National Highway Traffic Safety Administration Washington, D.C 1989 660 664
- Melvin JW Weber K Review of Biomechanical Impact Response and Injury in the Automotive Environment Report No. DOT HS 807 042 U.S. Departmentof Transportation, National Highway Traffic Safety Administration Washington, D.C. 1985
- Morgan RM Schneider DC Eppinger RH Nahum AM Marcus JH Awad J Dainty D Forrest S Interaction of human cadaverand Hybrid III subjects with a steering assembly Proc 31st Stapp CarCrash Conf Society of Automotive Engineers Warrendale, PA 1987 pp 79 93
- Saul RA Sullivan LK Marcus JH Morgan RM Comparison of current anthropomorphic test devices in athree-point belt restraint system Proc 27th Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1983 445 462
- Shaibani SJ Khaewpong N Identification of chest injuries from changes in transverse sections of the thorax during blunt impact Dept of Transportation Natonal Highway Traffic Safety Administration Washington, DC Feb 1990 DTHNH22
- Walfisch G Chamouard F Lestrelin D Tarriere C Brun Cassan F Mack P Got C Guillon F Patel A Hureau J Predictive functions of thoracic injuries to belt wearers in frontal collisions and their conversion into protection criteria Proc 29th Stapp Car Crash Conf Society of Automotive Engineers Warrendale, PA 1985 49 68