Preliminary Analysis of the CO2 Fire Suppressant Distribution System for Space Station Freedom
Annotation ability available
Sector:
Language:
English
Abstract
To date, the fire suppression capabilities resident on United States spacecraft have been somewhat limited and highly crew dependent. The spectrum of previous suppression systems extends from the food rehydration water on Mercury and Gemini to the Halon distribution system and portable extinguishers flown on the Orbiter and Spacelab. The challenge presented by Space Station Freedom of assuring crew safety while maintaining a permanent manned presence in space has led to the design of a more extensive fire suppression distribution system. This is the first time that carbon dioxide will be used as the suppressant. This choice partially overcomes present problems of post-fire toxic substance cleanup and monitoring of two phase Halon quantities in microgravity. During the development and testing activities surrounding this system, analyses have been performed to predict system conditions such as suppressant discharge flow rates, suppressant state, and dilution times. These preliminary results can provide a basis for estimating the capability of the baseline design to meet the WP01 derived system requirements.
Authors
Citation
Gedcke, J., Mohamadinejad, H., and Gard, M., "Preliminary Analysis of the CO2 Fire Suppressant Distribution System for Space Station Freedom," SAE Technical Paper 911473, 1991, https://doi.org/10.4271/911473.Also In
References
- Diamant, Bryce, L. Past and Present Environmental Control and Life Support On Manned Spacecraft SAE 901210 Hunstville AL July 1990
- Boeing Corporation FDS Distribution Exorack LAB Tube Schematic D683-15700 Huntsville, AL February 9 1990
- Boeing Corporation Fire Suppression Concept Confirmation Test D683-10474 Huntsville, AL
- Martin Marietta Corporation Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA'85/FLUINT) User's Manual Version 2.3 Denver, CO March 1990
- Boeing Corporation Fire Detection and Suppression System POST Plan D683-10326-5 Huntsville, AL October 30 1990