Ceramic wall-flow type diesel particulate filters (DPF) are being investigated for the aftertreatment systems of heavy duty engines. To use ceramic DPF more reliably and easily, electric heating regenerations are studied varying combustion air flow rates and amounts of accumulated soot.
Despite electric heater capacity limitations, it is possible to regenerate DPF at a certain combustion air flow rate without thermal shock failure. The maximum withstood temperature against thermal shock failure of electric heating regeneration is similar to that of diesel burner regeneration on DPF with a nine inch diameter and a twelve inch length.
Recommended Content
Authors
Citation
Kitagawa, J., Hijikata, T., and Yamada, S., "Electric Heating Regeneration of Large Wall-Flow Type DPF," SAE Technical Paper 910136, 1991, https://doi.org/10.4271/910136.Also In
References
- Cornetti G. M. et al “Italian City buses with Particulate Traps” SAE Paper No. 900114 1990
- Norbye J. “Truck Industry Meeting Diesel Emission Challenge” High Speed Diesel & Drives 22 July 1990
- Pattas K. Samaras Z. Patsatzis N. Michalopoulau; C. “On-Road Experiance with Trap Oxidizer Systems Installed on Urban Buses” SAE Paper No. 900109 1990
- Barris M. “Durability Studies of Trap Oxidizer Systems” SAE Paper No. 900108 1990
- Higuchi N. Mochida S. Kojima; M. “Optimized Regeneration Conditions of Ceramic Honeycomb Diesel Particulate Filters” 1983 SAE Trans. 830078
- Kitagawa J. Hijikata T. Makino; M. “Effect of DPF Volume on Thermal Shock Failures during Regeneration” SAE Paper No. 890173 1989
- Mizuno H. Kitagawa J. Hijikata; T. “Controlling of Heating Rate for Safe Regeneration of Ceramic Honeycomb Diesel Particurate Filter” 1988 SAE Trans. 880002
- Kitagawa J. “Thermal Shock failures of Ceramic Diesel Particulate Filters” ATA Paper E2.7 1989 6
- Kitagawa J. Hijikata T. Makino; M. “Analyses of Thermal Shock Failure on Large Volume DPF” SAE Paper No. 900113 1990