Separate Controls of Meter-in and Meter-out Orifices in Mobile Hyraulic Systems
Annotation ability available
Sector:
Language:
English
Abstract
The development during the last decades in mobile fluid power control has been directed to achieve better controllability and better energy utilization. However, most valve concepts still use mechanical or hydro-mechanical control of the main control valves, but the use of electro-hydraulic control systems is increasing. The main valves are with few exceptions of spool type. Control demands such as load sensing and pressure compensation are normally fulfilled by adding attachment valve units for each purpose. Unfortunately, the additional valves make the system more complex. If the main valves can be made more intelligent, the number of attachment valves can be reduced.
A major disadvantage (and an advantage) of the spool valve is that meter-in and meter-out orifices are mechanically linked to each other and thus giving a less flexible control. It would definitely increase flexibility if one could separate the controls of meter-in and meter-out orifices. A natural way to do this is to exchange the spool valve with seat valves. This is a well-known technique which has been used in heavy industrial applications for several years. However, in mobile fluid power systems the use of seat valves has normally been restricted to pressure relief valves and check valves, as reasonably cheap proportionally controlled seat valves did not earlier exist.
This paper deals with the ways to control (using a computer) an actuator with four electrohydraulic proportionally controlled seat valves in a system with an electrohydraulic controlled variable pump. The analysis is made by using both simulation and experiments on a test set-up controlled by a personal computer.
The main task of this investigation is to examine the control strategies offered by separate controls of meter-in and meter-out orifices. A discussion is also made of demands requested by this control strategy on the components, e.g the valves.
Recommended Content
Technical Paper | Condition Monitoring of a Hydraulic Valve Through On-Line Estimation of the Valve Orifice Area Profile |
Technical Paper | A Model-Based Design Analysis of Hydraulic Braking System |
Technical Paper | Solenoid Operated Cartridge Valves |
Authors
Topic
Citation
Jansson, A. and Palmberg, J., "Separate Controls of Meter-in and Meter-out Orifices in Mobile Hyraulic Systems," SAE Technical Paper 901583, 1990, https://doi.org/10.4271/901583.Also In
References
- Andersson B.R. ‘On the Valvistor - A Proportionally Controlled Seat Valve’ Division of Fluid Power Control Linköping, Sweden 1984
- Krus P. Palmberg J-O ‘Integration of Simulation and Measurement in Time and Frequency Domains’ 2nd International Conference on Fluid Power Transmission and Control Hangzhou, China 1989
- Lantto B. Jansson A. Palmberg J.O. “A New Concept of Computer Controlled Electrohydraulic Systems. The P-Q Pump. Combined Pump and Valve Control” Fluid Power Components and Systems, Second International Fluid Power Workshop Bath, England 1989
- Langen, A. ‘Experimentelle und analytische Untersuchungen an vorgesteurete hydraulisch-mechanischen und elekro-hydraulischen Pumpenregelungen’ RWTH Aachen, West Germany
- Backé, W. “Design Systematics and Performance of Cartridge Valve Controls” International Conference on Fluid Power Tampere, Finland 1987
- Warren, G.K. “Efficient and Fexible Hydraulic Systems for Mobile Equipment” 7th Aachener Fluidtechnisches Kolloquium Aachen, West Germany 1986