This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Performance Comparison of HFC-134a and CFC-12 with Various Heat Exchangers in Automotive Air Conditioning Systems
Annotation ability available
Sector:
Language:
English
Abstract
This paper reviews vehicular wind tunnel tests that were carried out on two automotive air conditioning systems. The test data compare the performance of the air conditioning systems utilizing refrigerants HFC-134a and CFC-12 with various heat exchangers. Heat exchanger selection was found to influence refrigerant charge levels. This will be important in the future when more costly HFC-134a becomes the refrigerant of choice.
CFC-12 HAS LONG BEEN THE REFRIGERANT OF CHOICE for automotive air conditioning systems. Unfortunately, scientists have linked CFC-12 and other fully halogenated refrigerants to the destruction of the world's ozone layer. In addition, CFC-12 and other fully halogenated refrigerants are “greenhouse” gases, accounting for about 25% of the global warming that has taken place (1). The most promising environmentally safe refrigerant for replacement of CFC-12 appears to be HFC-134a. The automotive engineering community needs a better understanding of how HFC-134a will affect air conditioning performance if it is to adequately design future systems. This paper compares the performance of CFC-12 and HFC-134a during air conditioning tests conducted in a “vehicular” wind tunnel.
Recommended Content
Technical Paper | PERFORMANCE COMPARISON OF HFC-134a AND CFC-12 IN AN AUTOMOTIVE AIR CONDITIONING SYSTEM |
Technical Paper | Current Development Status of HFC-134a for Automotive Air Conditioning |
Authors
Citation
Struss, R., Henkes, J., and Gabbey, L., "Performance Comparison of HFC-134a and CFC-12 with Various Heat Exchangers in Automotive Air Conditioning Systems," SAE Technical Paper 900598, 1990, https://doi.org/10.4271/900598.Also In
References
- Atmosphere CFCs Responsible for 25% of Global Warming II 1 2 Spring-Summer 1989
- Goodremote C.E. Guntly L.A. Costello N. F. 1988 SAE Paper No. 880445 Compact Air Cooled Air Conditioning Condenser SAE International Congress and Exposition Detroit, Michigan February 29 March 4 1988
- Struss R.A. Henkes J.P. El-Bourini M.R. Eigenberger J.J. 1989 SAE Paper No. 890226 Refrigeration Charge Reduction Through the Application of a New Vehicular Condenser SAE International Congress and Exposition Detroit, Michigan February 27 March 3 1989
- Clifford G.E. 1984 Heating Ventilating and Air Conditioning Reston Publishing Company, Inc. 96