A preliminary design concept for an ionization gauge to detect leaks in fluid carrying lines external to Space Station Freedom has been developed. The gauge requires less than 5 watts of power, weighs less than 4 pounds, and meets the performance requirements.
Authors
Topic
Citation
Hertel, R. and Heppner, R., "Leak Detection for Space station Freedom Fluid Lines," SAE Technical Paper 891448, 1989, https://doi.org/10.4271/891448.Also In
References
- Space Station External Contamination Control Requirements JSC 30426 NASA Lyndon B. Johnson Space Center Houston, TX
- Private Communication David C.E. McDonnell Douglas Corporation