This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
A Zero-Gravity Thermodynamic Vent System for a Liquid Hydrogen Tank
Annotation ability available
Sector:
Language:
English
Abstract
A Thermodynamic Vent System (TVS) to vent a liquid hydrogen tank in low gravity was designed and built by Sundstrand. The TVS was designed and built to a General Dynamic Space Systems Division (GDSSD) specification and was based on earlier laboratory work and design studies done by GDSSD for NASA. The TVS assures that superheated vapor is vented from the tank to control tank pressure with minimum loss of fuel. Major components of the TVS are a swirl flow heat exchanger, an electric motor-driven mixer pump, a fully redundant electronic inverter, and a redundant combined regulator and shutoff valve. The TVS has been extensively tested; the test results compare well with analytical predictions. This paper will describe the system and discuss the test results.
Recommended Content
Authors
Citation
Halsey, D., "A Zero-Gravity Thermodynamic Vent System for a Liquid Hydrogen Tank," SAE Technical Paper 871521, 1987, https://doi.org/10.4271/871521.Also In
References
- Merino F “Heat Exchanger for Centaur Fuel Tank Vent During Coast;” Convair Astronautics Report CA-E-44 6 Apr 1960
- Stark J.A. Blatt M.H. “Cryogenic Zero-Gravity Prototype Vent System,” Report No. GDC-DDB67-006; prepared under NASA Contract NAS8-20146; General Dynamics Convair Division Oct 1967
- Sterkentz W.H. “Liquid Propellent Thermal Conditioning System,” Lockheed Missiles and Space Company Report K-07-68-2, prepared under NASA Contract NAS3-7942 15 Aug 1968
- Erickson R.C. “Space LOX Vent System,” General Dynamics Convair Division Report No. CASD-NAS-75-021; prepared under NASA Contract NAS8-26972 30 Apr 1975
- Crain B.J. Bell K.J. “Forced Convection Heat Transfer to a Two-Phase Mixture of Water and Steam in a Helical Coil,” AICME: Symposium Series, No. 131 69
- Sorensen G.L. Niggemann R.E. Bassett C.E. Sedillo M. “A Zero-Gravity Thermodynamic Vent System for the Shuttle/Centaur Hydrogen Tank” Intersociety Conference on Environmental Systems July, 1984