This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Phase Change Water Recovery for Space Station - Parametric Testing and Analysis
Annotation ability available
Sector:
Language:
English
Abstract
Vapor Compression Distillation (VCD) technology for phase change recovery of potable water from wastewater has evolved as a technically mature approach for use aboard the Space Station. A program to parametrically test an advanced preprototype Vapor Compression Distillation Subsystem (VCDS) was completed by Life Systems for the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) during 1985.
In parallel with parametric testing, a hardware improvement program was initiated to incorporate and verify certain key improvements into the advanced preprototype VCDS following initial parametric tests. Specific areas of improvements included long-life, self-lubricated bearings, a lightweight, highly-efficient compressor and a long-life magnetic drive. These improvements are now incorporated and verification testing started.
The advanced preprototype VCDS was designed to reclaim 95% of the available wastewater at a nominal water recovery rate of 1.36 kg/h (3.0 lb/hr) and 308 K (95 F) condenser temperature. While this performance was maintained for the initial testing, a 300% improvement in water production rate (4.1 kg/h (9.0 lb/hr)) with a corresponding lower specific energy was achieved following incorporation of the improvements.
The paper presents a summary of the results of the parametric test program conducted. Testing involved the characterization of key VCDS performance factors (water production rate, water quality and specific energy) as a function of recycle loop solids concentration, distillation unit temperature and fluids pump speed. The objective of this effort was to expand the VCDS data base to enable defining optimum performance characteristics for flight hardware development. Based upon the parametric testing results which were obtained, projections are made for a Phase Change Water Recovery Subsystem for the Space Station based upon the VCD concept. The projected unit processes 18.1 kg/day (40.0 lb/day) of wastewater, weighs, 36.1 kg(79 lb), has a volume of only 0.21 m3 (7.4 ft3) and requires only 84 W of electrical power for a specific energy of 76.8 W-h/kg (35 W-hr/lb).
Topic
Citation
Zdankiewicz, E. and Chu, J., "Phase Change Water Recovery for Space Station - Parametric Testing and Analysis," SAE Technical Paper 860986, 1986, https://doi.org/10.4271/860986.Also In
References
- Zdankiewicz, E. M. Schubert, F. H. “Development of an Advanced Preprototype Vapor Compression Distillation Subsystem (VCDS) for Water Recovery,” Final Report, Contract NAS9-16374, TR-471-4; Life Systems, Inc. Cleveland, OH May 1984
- Ellis, G. S. Wynveen, R. A. Schubert, F. H. “Development of a Preprototype Vapor Compression Distillation Water Recovery Subsystem” Final Report, Contract NAS9-15267, ER-312-4; Life Systems, Inc. Cleveland, OH August 1979
- Zdankiewicz, E. M. Price, D. F. “Phase Change Water Processing for Space Station,” SAE 851346 Presented at the Fifteenth Intersociety Conference on Environmental Systems San Francisco, CA July 1985