The Design and Experimental Use of a Chest Load-Distribution Transducer and Force-Indicating Legs for the Part 572 Dummy
Annotation ability available
Sector:
Language:
English
Abstract
The current Part 572 50th percentile male dummy's chest and legs only indirectly and incompletely measure the forces acting upon them - by spinal acceleration for the chest and by mid-femur axial force for the legs. A new chest and set of legs have been designed and are in experimental use in a Part 572 dummy which far more completely measure the forces acting upon them during crash testing.
CHEST LOAD-DISTRIBUTION TRANSDUCER - Through three independent beams, with a small triaxial load cell located at the end of each beam, the vector direction and magnitude of the load can be measured at six key locations on the rib cage during the dynamic testing of restraint systems. The effect of small changes in the restraint system on the forces experienced by the thoracic area of the dummy can now be quantified. Some of the experimental results are discussed.
FORCE-INDICATING LEGS - By use of these legs, femur and tibia triaxial, bending, and torsional loads can be measured along with tibia-femur (knee joint) shear loads and ankle upward bending loads. The knee joint also has force-deflection properties in shear. For the first time, these loads, induced by leg restraint systems, can be studied. Some of the experimental results are discussed.
Authors
Citation
Daniel, R. and Yost, C., "The Design and Experimental Use of a Chest Load-Distribution Transducer and Force-Indicating Legs for the Part 572 Dummy," SAE Technical Paper 811012, 1981, https://doi.org/10.4271/811012.Also In
References
- Adomeit D. Heger A. “Motion Sequence Criteria and Design Proposals for Restraint Devices in Order to Avoid Unfavorable Biomechanic Conditions and Submarining,” Proceedings of 19th Stapp Car Crash Conference 1975 139 165
- Adomeit D. “Evaluation Methods for the Biomechanical Quality of Restraint Systems During Frontal Impact,” Proceedings of the 21st Stapp Gar Crash Conference 1977 911 931
- Daniel R. P. Trosien K. R. Young B. 0. “The Impact Behavior of the Hybrid II Dummy,” Proceedings of the 19th Stapp Car Crash Conference 1975 117 137
- Viano D. C. et al “Bolster Impacts to the Knee and Tibia of Human Cadavers and an Anthropomorphic Dummy,” Proceedings of the 22nd Stapp Car Crash Conference 1978 403 428
- Cheng R. Denton R. A. King A. I. “Femoral Loads Measured by a Six-Axis Load Cell,” Proceedings of the 23rd Stapp Car Crash Conference 1979 261 288
- Nyquist G. W. “Static Force-Penetration Response of the Human Knee,” Proceedings of the 18th Stapp Car Crash Conference 1974 495 538
- Hering W. E. Patrick L. M. “Response Comparisons of the Human Cadaver Knee and a Part 572 Dummy Knee to Impacts by Crushable Materials,” Proceedings of the 21st Stapp Car Crash Conference 1977 1015 1053
- Viano D. C. “Considerations for a Femur Injury Criterion,” Proceedings of the 21st Stapp Car Crash Conference 1977 445 473
- SAE J-963 “Anthropomorphic Test Device for Use in Dynamic Testing of Motor Vehicles,” June 1968
- Yamada Hiroshi Evans F. G. “Strength of Biological Materials,” Krieger Publishing Co. Melbourne, Florida 1970 19 105
- United States Patent No. 3,841,163 to Daniel R. P. “Test Dummy Submarining Indicator System” Oct. 15 1974 and assigned to Ford Motor Company. Humanoid Corp. and Alderson Research Labs are licensees under this patent
- Foster J. K. et al “A Biomechanically-Based Crash Test Dummy,” Proceedings of the 21st Stapp Car Crash Conference 1977 974 1014