Abstract
Combustion efficiency of internal combustion engine is closely influenced by the air flow pattern in the engine cylinder. Some researchers use high-speed particle image velocimetry to visualize and measure the temporally and spatially resolved in-cylinder velocity flow fields in the optically assessable engine. However, the transparent cylindrical liner makes it difficult to accurately determine the particle displacements inside the cylinder due to the optically distorted path of scattering light from seeding particles through the curved liner. To correct for the distortion-induced error in the seeding particle positions through the optical liner, the distortion mapping function is modeled using the Gaussian optics theory. Two artificial flow patterns with 5 by 5 vectors were made to illustrate the mapping correction. Distortion-induced error of velocity vectors was precisely mapped in six different planes inside the cylinder. In addition, the in-cylinder PIV measurements in these six planes were applied to illustrate the distortion-induced error. Results show that velocity fields in the center plane did not exhibit much distortion-induced effect. However, the relative distortion-induced error percentage of ensemble velocity magnitude near the cylinder liner could reach as much as 2.1%, indicating that it is necessary to correct for optical distortion in this location. The distortion mapping function used in this study can provide an effective way to correct the distortion-induced error in the planar in-cylinder flow field measured through the transparent liner.
Recommended Content
Authors
Topic
Citation
Ge, P., Zhao, F., Hung, D., Pan, H. et al., "Distortion Mapping Correction of In-Cylinder Flow Field Measurements through Optical Liner Using Gaussian Optics Model," SAE Technical Paper 2017-01-0615, 2017, https://doi.org/10.4271/2017-01-0615.Data Sets - Support Documents
Title | Description | Download |
---|---|---|
Unnamed Dataset 1 |
Also In
References
- Abraham , P. , Reuss , D. , and Sick , V. High-Speed Particle Image Velocimetry Study of In-Cylinder Flows with Improved Dynamic Range SAE Technical Paper 2013-01-0542 2013 10.4271/2013-01-0542
- Chen , J. , and Katz , J. Elimination of peak-locking error in PIV analysis using the correlation mapping method Measurement science and technology 16 8 1605 2005 10.1088/0957-0233/16/8/010
- Reuss , D. L. , Megerle , M. , Sick , V. Particle-image velocimetry measurement errors when imaging through a transparent engine cylinder Measurement Science and Technology 13 7 1029 2002 10.1088/0957-0233/13/7/309
- Zha , K. , Busch , S. , Miles , P. , Wijeyakulasuriya , S. et al. Characterization of Flow Asymmetry During the Compression Stroke Using Swirl-Plane PIV in a Light-Duty Optical Diesel Engine with the Re-entrant Piston Bowl Geometry SAE Int. J. Engines 8 4 1837 1855 2015 10.4271/2015-01-1699
- Steenbergen , W. Reduction of beam refraction in optical pipe flow experiments by use of sheet-fabricated pipe walls Experiments in fluids 22 2 165 173 1996
- De, Witt , B. J. , Coronado-Diaz , H. , Hugo , R. J. Optical contouring of an acrylic surface for non-intrusive diagnostics in pipe-flow investigations Experiments in Fluids 45 1 95 109 2008 10.1007/s00348-008-0466-8
- Reeves , M. , Garner , C. P , Dent , J. C. , and Halliwell , N. A. Particle image velocimetry measurements of in-cylinder flow in a multi-valve internal combustion engine Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering 210 1 63 70 1996
- Yue , M. X. , Xie , F. , Zhang , J. , Yuan , Q. and Zhang , L. Aberrance and rectification of a round pipe for flow field visualization Journal of Experiments in Fluid Mechanics 29 1 87 91 2015
- Kang , K. H. , Lee , S. J. , Lee , C. M. , and Kang , I. S. Quantitative visualization of flow inside an evaporating droplet using the ray tracing method Measurement Science and Technology 15 6 1104 2004 10.1088/0957-0233/15/6/009
- Li , R. Y. , Huang , W. M. Method of radial distortion calibration for PIV measurement in a cylinder container with arbitrary curve-shaped J. University of Shanghai for Science and Technology 30 4 315 318 2008 10.13255/j.cnki.jusst.2008.04.015
- Liu , Y. P. , Hu , X. Y , Chen , J. L. , Wang , P. Y. , Du , Z. H. Direct Image Correction Algorithm for PIV Measurement of Flowfield within Circular Tube Journal of Shanghai Jiao Tong University 46 4 525 531 2013
- Chen , H. , Hung , D. L. S. , Xu , M. Zhuang , H. and Yang , J. Proper orthogonal decomposition analysis of fuel spray structure variation in a spark-ignition direct-injection optical engine Experiments in Fluids 55 4 1 12 2014 10.1007/s00348-014-1703-y
- Zhuang , H. , Hung , D. L. S. , Chen , H. Study of time-resolved vortex structure of in-cylinder engine flow fields using proper orthogonal decomposition technique Journal of Engineering for Gas Turbines and Power 137 8 082604 2015 10.1115/1.4029600