In this paper a model of Trailer Refrigeration Units, TRUs, has been developed to quantify the fuel economy and emissions benefits of alternative power systems. Trailer refrigeration units (TRUs) are refrigeration systems typically powered by a separate diesel engine, and they are used to deliver fresh and frozen food products. The products can be very sensitive to temperature variation and maintaining the proper environment is very important. The diesel engines currently used to power the refrigeration system can contribute to high amount of local emissions at the loading warehouse. A promising future alternative is the use of fuel cell auxiliary power units (APUs). In this paper we have developed a MATLAB/Simulink based modeling of TRUs, and we have used the model to quantify the benefits of alternative power systems. The simulation model consists of an unsteady thermal modeling of TRUs that is coupled to the APU. For the diesel engine a fuel and emissions map is incorporated into the model. From our simulations it was observed that the duty cycle, energy consumption, and emissions are highly influenced by the ambient operating temperatures. Some of the most interesting results were observed when the ambient air temperature was very high.
The second part of the simulation model consisted of fuel cell hybrid APU, which was also coupled to the TRU thermal model. From our simulations over typical duty cycles it was observed that the fuel cell hybrid system's energy efficiency was greater than the diesel engine; also, they have a great potential to reduce local emissions and noise which, is a great concern for TRUs. The fuel cell hybrid system performance was found to be dependent on component size and control strategy, and we have made a study of the important parameters, such as state of battery charge, fuel cell size, and storage capacity. A fuel cell system enables a new paradigm in TRU design, since an electrical powered system allows for the use of variable rpm electrical drives such as dc motors and scroll compressors. The introduction of these more efficient and flexible systems will allow for better temperature and refrigeration control in future systems.
Recommended Content
Authors
Topic
Citation
Kulkarni, C. and Dwyer, H., "Modeling and Performance of Trailer Refrigeration Units with Alternative Power Systems," SAE Technical Paper 2007-01-0764, 2007, https://doi.org/10.4271/2007-01-0764.Also In
References
- eTRU Market Study and Technology Assessment, Shurepower June 2005
- CARB 2003 Airbourne Toxic Control Measure for in-use Diesel Fueled Transportation Refrigeration Units (TRUs) and TRU Generation Units, and Facilities
- Transport Refrigeration Equipment: Cost-Effective Emissions Reduction September 2004
- Abelson, Paul “Understanding Reefers” Landline Magazine March April 2001
- Transport Refrigeration Units December 2004
- Kulkarni, Chintamani “Modeling and Performance Analysis of Trailer Refrigeration Units with Alternate Power Systems’ University of California Davis 2007
- Flores, S. E. Cleland A. C. Cleland D. J. “Prediction of the Dynamic Thermal Behavior of Walls for Refrigerated Rooms using Lumped and Distributed Parameter Models” International Journal of Refrigeration 24 2001 272 284
- Kulkarni, Manohar. Hong, Feng “Energy Optimal Control of a Residential Space-Conditioning System Based on Sensible Heat Transfer Modeling” Building and Environment 39 2004 31 38
- Antonopoulos K.A. Valsamakis S. P. “Effects of Indoor and Outdoor Heat Transfer Coefficients and Solar Absorption on Heat Flow Through Walls” Energy 18 3 259 271 1993
- Alhama, F. Lopez-Sanchez J. F. Gonzalez C. F. “Heat Conduction Through a Multilayered Walls with Variable Boundary Condition” Energy 22 8 797 803 1997
- Hudson, G Underwood CP A simple building modeling procedure for Matlab/Simulink Proceedings of Building Simulation 2 1999 777 83
- Mader, Pippin “Truck Trailer Refrigeration Unit Emissions Characterization” University of California Davis 2003
- Operating Manual, Truck Refrigeration Unit, Carrier Transicold 1996
- Incropera, F. P. Dewitt, D. P. “Introduction to Heat Transfer” Fourth Wiley 2001
- Lin, C. C. “Modeling and Control Strategy Development for Hybrid Vehicles” University of Michigan 2004
- Larminie, James Dicks, Andrew “Fuel Cell Systems Explained” 2nd John Wiley & Sons Inc 2003
- National Renewable Energy Laboratory Center for Transportation Technologies and Systems 2002 U.S. Department of Energy 2002
- Boettner, Daisie. D etal. “Component Power Sizing and Limits of Operation for Proton Exchange Membrane (PEM) Fuel Cell/Battery Hybrid Automotive Applications” ASME International Mechanical Engineering Congress and Exposition 70 2001