A Study on Design Factors for the Air Ventilating System of Highway Express Buses
Technical Paper
2006-01-3455
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
In efforts to prevent airflow noise and conserve heated and/or cooled air, express bus design has favored fixed windows, double glasses and closed structures with lower rates of ventilation. However, because there are many passengers in an express bus at the same time, offensive odor, carbon dioxide and other contaminants may accumulate in the bus's indoor. If sufficient amounts of ambient air are not brought into or distributed throughout the passenger compartment of the bus, in-bus air problems may result. An air ventilating system of the express bus that is properly designed, and that has a good performance of natural ventilation, can promote the air quality of the passenger compartment and the comfort of passengers. In order to design an effective ventilating system of the express buses, some design factors such as air inlet/outlet positions, air distribution, proportion of ambient air, and airflow control are considered computationally and experimentally in this work.
Recommended Content
Authors
Citation
Shin, S., Jeong, B., and Lim, S., "A Study on Design Factors for the Air Ventilating System of Highway Express Buses," SAE Technical Paper 2006-01-3455, 2006, https://doi.org/10.4271/2006-01-3455.Also In
References
- Oshio Fuyuki Kurosaka Kenichi Okumura Kenji “Analysis of Air Ventilation Performance based on Aerodynamics Simulation” SAE Technical Paper 2001-01-0296
- Patankar S.V. “Numerical Heat Transfer and Fluid Flow” Hemispher Publishing 1980
- Makowski Francis T. Kim Sung Eun “Advances in External-Aero Simulation of Ground Vehicles Using the Steady RANS Equations” SAE Technical Paper 2000-01-0484
- Hucho Wolf-Heinrich “Aerodynamics of Road Vehicles” Butterworth-Heinemann Ltd. 1987
- Fluent 6 User's Manual Fluent Inc. 2002
- El-Sayed A F. Abdel Azim Nassief M M “An Investigation into the Aerodynamics of the External Flow Around a Bus” SAE Technical Paper 962173
- Kim Min-ho Lee Dae-hoon Lee Yoon-ki “A Numerical Analysis on the Optimum Distribution of an Air-conditioning Duct with Multiple Outlets in a Medium Bus” SAE Technical Paper 2001-01-2813
- Conceicao E.Z.E. Silva M.C.G. Viegas D.X. “Airflow Around a Passenger Seated in a Bus” HVAC&R Research 3 4 311 323 Oct 1997
- Galatsis Kosmas Wlodarski Wojtek et al “Vehicle Cabin Air Quality Monitor for Fatigue and Suicide Prevention” SAE Technical Paper 2000-01-0084
- Axelsson A Niklas Enwald Hans “Accuracy in Flow Simulations of Climate Control-Part 1: The Air Distribution System” SAE Technical Paper 1999-01-1200