A study has been conducted on a small engine cooling system in order to find a way to reduce common overheating problems at idle conditions and high engine speeds with restricted airflow. The system flow rates, pressure, and temperature characteristics were monitored at different positions in the system while engine speed was varied. The results show that by adjusting the flow rates according to certain variables, the overall effectiveness of the system is increased and overheating problems can be eliminated. The findings also show that this adjustment can be accomplished by incorporating a controllable electric water pump into the design. Dynamometer testing has also been conducted to show that, in addition to controlling flow rates, the use of the electric pump also possesses the potential of increasing the power output of the engine.
Recommended Content
Authors
Citation
Jawad, B., Zellner, K., and Riedel, C., "Small Engine Cooling and the Electric Water Pump," SAE Technical Paper 2004-32-0084, 2004, https://doi.org/10.4271/2004-32-0084.Also In
References
- Beard, R. A. Smith G. J. “A Method of Calculating the Heat Dissipation from Radiators to Cool Vehicle Engines,” SAE 710208
- Kargilis, Al “Design and Development of Automotive Engine Cooling Systems,” Alkar Engineering Company Southfield, MI 2000
- Lin, Changhua Saunders Jeffrey Watkins Simon “The Effects of Changes in Ambient and Coolant Radiator Inlet Temperatures and Coolant Flowrate on Specific Dissipation,” SAE 2000-01-0579
- Ramprabhu, R. Sathyanarayananan P. L. “Study of Pressure Drop Effect on Airflow in Baffle Tanks,” SAE 2003-01-1378 .
- Rocklage, Gerta M. Vogt Richard Riehl Guenther “Requirements on New Components for Future Cooling Systems,” SAE 2001-01-1767